2030_oo3A
Section 3:
User
lnformation
5.
Double click the Display
Data
file
(Dvno<xxx.fix)
I
6.
Click
"Send."
The sequence data
will be
sent.
The
process
takes
zpproximately 25 seconds.
Vl. Clear the Event Log
1. lfype
"FIELD"
and
press
ENTER
2. ilype
"L
CLEAR" and
press
ENTER
FIELD>L
CLEAR
Vll.
Load Default
Values
on
the Machine
1.
lJsing
the Model
2000 Front Panel
buttons,
Enter
the
Main Menu
Category:
IVIISCELLANEOUS, Scroll
to the Sub-Menu:
LOAD
DEFAULTS.
2. lPress the second button
from the
top on
the
front
of the
CPU.
(For
more
iLnformation on the
CPU Buttons, see
page Error!
Bookmark
not defined..)
3. 'Veriff
that the machine's
display changes
to
n'Defaults
Loaded."
4.
'Iype
"STATS
CLEAR"
and
press
ENTER
FIELD>STATS
CLEAR
Failure
to clear the statistics
may lead
to
machine
malfunction!
Vlll.
Disiconnect
Gable
1. .Disconnect
the communications
cable
from
the
front
of
the CPU.
2.
Replace
the electrical
enclosure cover?
being
careful
to
leave
enough slack
in
the display
cable
to allow
free movement
of the
front
panel.
lX. Reset
All
Milk and
Espresso
Settings
1. Using
the
Espresso and
Milk Setting
you recorded
in
step
I, reset
all timings
in the machine
2. Calibrate
the
machine
as
you
normally
would,
verifying
customer
satisfaction.
Acorto
2000s/i
Technical
SuPPort