Section 9 Refrigeration
Unjl
Weigh
Tray
Operating
Voltage:
:iVDC
Located
in
the base
of the refer unit, the
Weigh
magnet
located in
the center of,the tray lines up
bottom
center
of the refer
unit.
Tray
sits on 4 retainer
springs. The
with
the Fixed
Sensor located
in the
The weight
of the full
milk containers
presses
the
trav
dorvn
to the sensor,
and the
output voltage
of'
the sensor
decreases.
As the milk
empties,
the tray raises.
the
sensor
voltage
increases
and
"low
milk" light illuminates.
The
Weigh Tray
sensor
is ad.justable via the screw located
in the middle
of
the tray
Refer
Weigh
Tray
Quick
Tip
Viewing
the Milk
tiensor
in Test
Routines
1.
Enter
the
programming
menu and
access
the Main
Menu
Category:
TEST
ROU'TINES
2.
Scroll
to
tlle
Sub Menu Category:
M|LK LEVEL
3. with
the lulilk
rray
in
place
(no
mitk)
the disptay
should
read
140
4-
with
a
fulll
container
of milk
placed
on milk
tray,
the
display
should
read
approximately
185
Adjusting
Weigh'fray
The
Milk
Level
in test
routines
should
reflect 140 rvith
the
tr,a;-
in place
and
empty.
To
ad.iust
tray.
simply
tunr
the
adjustment
screw in
the
rniddle
of the
tray
until
the
displa"""
reads
140.
frnsure
tray
is in
place
and
springs
are
centered
over
iaised post
within
the refer
unit prior
to
ad.iustment
Adjustable
Magnet
Weight Scale
.ts
Spring
Acorto
2000s/i
Technical
Support
9-5i