SERIES 2500 METERING PUMPS
COMPACT DESIGN
TOTALLY ENCLOSED
OIL IMMERSED MECHANISM
MANUAL OR AUTO ADJUSTMENT
2500 001 TO 050 METERING PUMP
MODEL _____________________
SERIAL NO __________________

Questions and Answers

  • J
    Jessica GarnerAug 19, 2025
    What to do if my Acromet Water Pump has no flow?
    • H
      hayleychapmanAug 19, 2025
      If your Acromet Water Pump has no flow, the issue might stem from: * A closed valve in the discharge line: Open the valve. * Incorrect reassembly of the pump discharge valve during maintenance, specifically the ball stop cushion being missing: Reassemble it correctly. * Overload relay: Reset the switch after checking the cause and correcting it.
  • A
    Austin LarsonAug 22, 2025
    How to fix reduced flow rate in Acromet Water Pump?
    • E
      Elizabeth MartinAug 22, 2025
      A reduced or unstable flow rate in your Acromet Water Pump can be caused by: * A clogged valve: Clean the valve. * A worn valve seat: Replace the seat or valve. * An incorrect flow meter: Inspect the meter, repair, or change it. * Leakage from the relief valve: Inspect, repair, or change the valve. * Air leaking into the suction piping: Check for the leak source and repair it. * An air lock in the suction line: Review the suction pipework layout to eradicate air pockets. * A change in pump RPM: Correct the electric power sources and speed control.
  • B
    Beth JonesAug 25, 2025
    What to do if Acromet Water Pump stops working after operating normally?
    • J
      James AliAug 26, 2025
      If your Acromet Water Pump stops working after operating normally, consider these potential causes: * Overload relay: Reset the switch after checking the cause and correcting it. * Clogged discharge pipe: Clear the pipe. * Valve in discharge line closed: Open the valve. * Pump discharge valve incorrectly reassembled during maintenance (ball stop cushion missing): Reassemble correctly.
  • W
    watsonkatieAug 28, 2025
    Why is my Acromet Water Pump motor overheating?
    • M
      Mark MoranAug 28, 2025
      Overheating in your Acromet Water Pump motor can occur due to: * Improper voltage: Adjust the voltage to the motor specification. * Overload: (Refer to Section K). * Inadequate ventilation: Change the motor or relocate it.
  • N
    Nicole GarciaAug 31, 2025
    How to troubleshoot liquid leakage from Acromet Water Pump adaptor drain?
    • P
      philip60Aug 31, 2025
      Liquid leakage from the Acromet Water Pump adaptor drain is caused by: * Ruptured diaphragm: Check/replace the diaphragm.
  • T
    thompsonleeSep 3, 2025
    How to solve overload issue in Acromet Water Pump?
    • L
      laneannaSep 3, 2025
      An overload in your Acromet Water Pump can be due to: * Improper Oil: Change the oil. * Discharge pressure too high: Lower to permissible pressure. * Erratic noise of pump valves: Clean the valves or Increase pressure difference (i.e., install back pressure valve).
  • D
    David MunozSep 6, 2025
    Why Acromet Water Pump has reduced flow rate and cavitation noise?
    • D
      Daniel VegaSep 6, 2025
      The Acromet Water Pump may have a reduced or unstable flow rate, and cavitation noise may be apparent due to: * Insufficient NPSH available: This could be due to a suction pipe diameter being too small or the suction lift being too great. Enlarge the suction pipe, install an accumulator in the line close to the pump, or raise the level of the tank or liquid level. * Viscosity of the liquid being too high: Heat or lower the viscosity by other means, increase the suction pipe diameter, or increase the suction pressure. * Vapor pressure being high: Lower the liquid temperature at the inlet port or raise the liquid level. * Suction piping and/or valve clogged: Clean the affected components. * Suction strainer clogged or too small: Clean or replace it with a larger unit.
  • J
    John YoungSep 9, 2025
    What causes knocking sound in Acromet Water Pump gearbox?
    • M
      mark90Sep 9, 2025
      Knocking sound in the gearbox of Acromet Water Pump is caused by: * Excessive discharge pressure: Check the discharge pressure.
  • A
    Angela OconnellSep 12, 2025
    What to do with liquid end noise in Acromet Water Pump?
    • V
      Vanessa GibsonSep 12, 2025
      Liquid end noise in Acromet Water Pump may be caused by: * Rhythmic noise of pump valves: This is normal. * Clogged discharge or suction valve: Clean the valve.
  • J
    Jeremiah LoweNov 15, 2025
    Why Acromet Water Pump does not start?
    • C
      Cassie BensonNov 15, 2025
      Your Acromet Water Pump might not be starting due to several reasons: * A blown electrical fuse: In this case, check the cause and change to a suitable capacity fuse. * The electrical overload relay trips: Change the relay capacity to the correct value. * Electrical wiring breakdown or defective contact: Change or reconnect the wiring. * Low voltage: Find the cause and correct the difference in supply voltage and the rated voltage of the motor. * Defective motor: Check and replace the motor. * Excessive pressure in the discharge line: Reduce the pressure. * Valve in the discharge line closed: Open the valve. * Pump discharge valve incorrectly reassembled during maintenance (ball stop cushion missing): Reassemble correctly. * Air in the liquid end: Relieve pressure in the...