107
Electrical Data AWM-G-2009
Electrical Data - Cooling Only (R410A)
MODEL
INDOOR UNIT A5WM 311
OUTDOOR UNIT A5LC 28C
INDOOR MOTOR
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 71
RATED RUNNING CURRENT A 0.30
MOTOR OUTPUT W IP24
POLES 4
OUTDOOR MOTOR
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 142
RATED RUNNING CURRENT A 0.62
MOTOR OUTPUT W 75
POLES 6
COMPRESSOR
INSULATION GRADE CLASS E
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
CAPACITOR mF 45.0
RATED INPUT POWER W 2360
RATED RUNNING CURRENT A 11.27
LOCKED ROTOR AMP. A 63
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
Electrical Data - Heat Pump (R410A)
MODEL
INDOOR UNIT A5WM 301R
OUTDOOR UNIT A5LC 28CR
INDOOR MOTOR
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 71
RATED RUNNING CURRENT A 0.30
MOTOR OUTPUT W IP24
POLES 4
OUTDOOR MOTOR
INSULATION GRADE CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 142
RATED RUNNING CURRENT A 0.62
MOTOR OUTPUT W 75
POLES 6
COMPRESSOR
INSULATION GRADE CLASS E
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
CAPACITOR mF 45.0
RATED INPUT POWER (COOLING) W 2360
RATED INPUT POWER (HEATING) W 2242
RATED RUNNING CURRENT (COOLING) A 11.27
RATED RUNNING CURRENT (HEATING) A 10.70
LOCKED ROTOR AMP. A 63
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.