EasyManuals Logo
Home>Acson>Air Conditioner>AWM 25G

Acson AWM 25G User Manual

Acson AWM 25G
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
47
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
General Data - Heatpump Only (R22)
MWM 009GR
MLC 009CR
Btu/h 9000
W 2640
Btu/h 9000
W
2640
W 910
W 750
A
4.0
A 3.4
V/Ph/Hz 220-240/1/50
W/W 2.9
W/W
3.52
R22
OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL
HIGH l/s / cfm 130 / 275
MEDIUM l/s / cfm 106 / 225
LOW l/s / cfm
83 / 175
dBA 40 / 35 / 29
HEIGHT mm/in 260 / 10.2
WIDTH mm/in
799 / 31.5
DEPTH mm/in 198 / 7.8
HEIGHT mm/in 337 / 13.3
WIDTH mm/in 857 / 33.7
DEPTH mm/in
270 / 10.6
kg/lb 10/22.05
mm/in 16 / 0.63
l/s / cfm
307 / 650
dBA 45
HEIGHT mm/in 495/19.5
WIDTH mm/in 600/23.6
DEPTH mm/in
245/9.7
HEIGHT mm/in 575/22.6
WIDTH mm/in 715/28.1
DEPTH mm/in
330/13.0
kg/lb 28/61.73
FLARE VALVE
LIQUID mm/in 6.35 / 1/4
GAS mm/in
9.52 / 3/8
kg/lb 0.75/1.65
REFRIGERANT CONTROL (EXPANSION DEVICE)
MODEL
OUTDOOR UNIT
INDOOR UNIT
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
EER
COP
PACKING DIMENSION
OUTDOOR UNIT
UNIT WEIGHT
CONDENSATE DRAIN SIZE
SOUND PRESSURE LEVEL
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
UNIT DIMENSION
AIR FLOW
INDOOR UNIT
CONTROL
AIR DISCHARGE
OPERATION
UNIT DIMENSION
PACKING DIMENSION
AIR FLOW
SOUND PRESSURE LEVEL (H/M/L)
AWM 09GR
ALC 09CR
Downloaded from AC-Manual.com Manuals

Other manuals for Acson AWM 25G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Acson AWM 25G and is the answer not in the manual?

Acson AWM 25G Specifications

General IconGeneral
BrandAcson
ModelAWM 25G
CategoryAir Conditioner
LanguageEnglish

Related product manuals