WM301R VS SL30CR
WM07 / 10 / 15 / 20 / 25 / 301R VS SL07 / 10 / 15 / 20 / 25 / 30BR
5WM301R VS 5SL28CR
There must be a double pole
switch with a minimum 3mm
contact gap and fuse/circuit
breaker as recommended in
the fixed installation circuit.
!
Indoor Unit
Terminal Block
Outdoor Unit
Terminal Block
Power Supply Cable
Outdoor Coil Sensor Connection Wire
(8m long) attached in the indoor unit
There must be a double pole
switch with a minimum 3mm
contact gap and fuse/circuit
breaker as recommended in
the fixed installation circuit.
!
Indoor Unit
Terminal Block
Outdoor Unit
Terminal Block
Power Supply Cable
Outdoor Coil Sensor Connection Wire
(8m long) attached in the indoor unit
4WV
OF
COMP
N2
N1
L
4WV
OF
COMP
L
N
S
R
N
T
4WV
OF
COMP
N2
N1
L
4WV
OF
COMP
L
N
A
S
R
N
T
WM301R VS SL30CR (3 Phase)WM201 / 251R VS SL20 / 25BR (3 Phase)
Outdoor Coil Sensor Connection Wire
(8m long) attached in the indoor unit
Outdoor Coil Sensor Connection Wire
(8m long) attached in the indoor unit
There must be a double pole
switch with a minimum 3mm
contact gap and fuse/circuit
breaker as recommended in
the fixed installation circuit.
!
Indoor Unit
Terminal Block
Outdoor Unit
Terminal Block
Power Supply Cable
Indoor Unit
Terminal Block
Outdoor Unit
Terminal Block
There must be a double pole
switch with a minimum 3mm
contact gap and fuse/circuit
breaker as recommended in
the fixed installation circuit.
!
Power Supply Cable
IMPORTANT : * The figures shown in the table are for information purpose only. They should be checked and selected
to comply with the local/national codes of regulations. This is also subject to the type of installation
and conductors used.
** The appropriate voltage range should be checked with label data on the unit. ETL listed is only applicable to 60Hz
power supply only.
Model Indoor WM 071/ 101/ 151 R WM201/ 251/ 301 R 5WM301R WM301 R WM201/ 251/ 301 R WM301 R
Outdoor SL07/ 10/ 15BR SL20/ 25/ 30BR 5SL28CR SL30CR SL20/ 25/ 30BR SL30CR
Voltage range**
220V-240V/ 1Ph/ 50Hz + or 208V-230V/ 1Ph/ 60Hz + 380V-415V/ 3Ph/ 50Hz +N+
Power supply cable size* mm
2
1.5 2.5 2.5 4 1.5 1.5
Number of wires 3 3 3355
Interconnection cable size* mm
2
1.5 2.5 2.5 2.5 1.5 1.5
Number of wires 5 5 5664
Recommended fuse A 15 20 20 25 15 15