9
3. APPLICATION INFORMATION
Operating Range
Ensure the operating temperature is in allowable range.
Cooling only
Heatpump
Caution :
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
Coolin
g
Outdoor temp. (°CDB)
Indoor temp.
(
°CWB
)
0
19
35
15
46
24
54
STD
HIGH AMBIENT
UNIT
LOW AMBIENT
KIT
Heatin
g
Outdoor temp. (°CWB)
Indoor temp.
(
°CDB
)
-9
15 21
6
27
18
STD
Coolin
g
Outdoor temp. (°CDB)
Indoor temp.
(
°CWB
)
0
19
35
15
46
24
54
STD
HIGH AMBIENT
UNIT
LOW AMBIENT
KIT