EasyManua.ls Logo

ACT Quantum - Air Filter; Power Modules Inspection

ACT Quantum
5 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
710-00039.5
2
2
QUANTUM CHARGER PREVENTIVE MAINTENANCE
The Quantum charger streamlined design emphasizes ease of maintenance. Preventive Maintenance is
mandatory annually to maintain warranty twice a year is recommended.
Below is the list of the maintenance procedures:
1) Air Filter
Regularly inspect air filter and clean or replace as necessary. Location and environmental conditions
must be taken into account when determining the frequency that the filter is cleaned or replaced. The
air filter can be blown out or washed in warm soapy water (the filter must be completely dried prior to
reinstall).
The following are general guidelines in regard to cleaning or replacing the air filter:
Environmental
Condition
Application Example
Recommended Filter
Replacement Cycle
Normal
A normal daily operation Conventional Charging
basic material handling of clean product in dry
environments.
Annually
Severe
Extended operating hours or constant use when
Fast or Opportunity charging in dusty, hot but dry
environments.
Bi-Annually
Extreme
All dusty or sandy conditions such as in cement
plants, lumber or flour mills, coal dust or stone-
crushing areas.
Corrosive atmosphere such as in chlorine or salt-
sea air environments.
Quarterly
2) Power modules Inspection
Pull out the power module and Inspect DC connector for any discoloration or deformation. Reinstall
the PMs and ensure that the PMs are fully seated, and the tabs are flushed. Tighten the bolts all
the way by hand and make sure they are secured.
3) DC Backplane Inspection