Installation (Continued)
3. Join two lengths of extension tubing
by using tube connector (Ref. No.
17) and two clamps (Ref. No. 20).
4. Attach extension tubing to (Ref. A)
and secure with hose clamp (Ref. No.
10).
5. Insert pump into opening and hand
tighten.
6. To adjust pump delivery, unscrew
top grip (Ref. No. 1) and slide tubing
(Ref. No. 9 or Ref. No. 11) over rod
to limit pump stroke.
7. For various size drums, tubing (Ref.
No. 18) can be cut to fit specific
drum.
8. Entire pump head (Ref. No. 4) can be
rotated to desired location; when
operating the pump, you should
stand to the side or in back of the
spigot.
PAIL ADAPTER INSTALLATION
1. This adapter (Ref. No. 14) is
designed to fit senior (metal ring)
flexspout closures.
2. Screw adapter (Ref. No. 14) on male
threads at bottom of pump (Ref. No.
13). Tightly secure adapter.
3. Remove cap on FLEXSPOUT closure
and remove diaphragm (Ref. B).
Insert tube extension into side, then
snap over the other side.
4. To remove pump with adapter from
pail, pull towards side of pail and
snap off making sure to hold pail
down.
Operation
1, The pump is now ready for
operation. Liquids should begin
flowing on second or third upstroke.
If slight leakage should occur, simply
tighten packing nut (Ref. No. 2) on
top of pump.
NOTE: Tighten only enough to prevent
leakage. Excessive tightening will
damage the packing and cause more
leakage.
2. When finished pumping, place cap
(Ref. No. 16) on end spout (Ref. No.
15) to prevent dripping.
3. If pump is removed from drum, rinse
thoroughly in liquid that is
compatible with both the pump and
fluid. For questions about chemical
compatibility, contact your chemical
supplier.
Maintenance
Normal maintenance is not required. If
pump leaks at the top replace packing
gland.
Models 6008 and 6009
3
Action Operating Instructions and Parts Manual
90-Day Limited Warranty