FAC-SIMILE
Code : PA7A00
PUMP PA1 70 - 230V
230 Volt - 50 Hz - IP 55 - 550W - 2,5 A
2800 rpm - Condensator: 450 v-16 µF
Weight Kg.: 8
ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS)
EN
EC DECLARATION OF CONFORMITY
(Annex II A DIR. 2006/42/EC)
THE MANUFACTURER
We, ADAM PUMPS S.p.A., with our registered ofce in Via della Resistenza, 46/48, 41011, Campogalliano (MO), ITALY; represented
by Davide Stassi, authorised to compile the relevant technical le at the undersigned premises,
DECLARES THAT THE MACHINE
Used as a diesel fuel pump to be integrated into a system for transferring fuel from a gravity tank.
COMPLIES WITH DIRECTIVES
Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/
EC.
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the
Member States relating to electromagnetic compatibility.
Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the
Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits.
Directive 2014/68/EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the
Member States relating to the making available on the market of pressure equipment.
Place and date of the document
Campogalliano, 1st October 2015
Adam Pumps spa
Via della Resistenza 46/48 - 41011 Campogalliano (MO) ITALY
Tel +39 059 528128 - Fax +39 059 528437
www.adampumps.com - info@adampumps.com
the use and maintenance manual must be carefully stored near the machine in an environment protected against
humidity and heat. the manual must accompany the machine if sold. it is prohibited to damage, modify or remove any
part of the manual.
USE AND MAINTENANCE MANUAL
Machine: DIESEL FUEL PUMP
Models: PA1 70A, PA2 80, PA2 100, PA3 150
UM033
11/2017 - rev. 06
Batch of
Model
Description
Technical specications
Weight
The legal representative

Questions and Answers

  • T
    Timothy LoweAug 9, 2025
    What to do if Adam Pumps Water Pump does not start?
    • M
      morrowrachelAug 9, 2025
      If your Adam Pumps Water Pump doesn't start, first check for a power failure by inspecting the electrical connections and safety devices. If the circuit breaker has tripped, ensure the pump is used under recommended operating conditions. Also, verify there are no obstructions in the pump body or suction/discharge lines that might be blocking the impeller. If none of these solutions work, there may be a defective motor and you should contact the dealer (fault code M1).
  • H
    hrobersonAug 25, 2025
    What to do if Adam Pumps PA2 100 is leaking liquid?
    • B
      Barbara GilbertAug 26, 2025
      If you notice a liquid leak in your Adam Pumps Water Pump, first ensure all clamps are properly tightened. If the leak persists, check the gaskets for wear and replace them if necessary. Also, verify that you are using compatible liquids. If the shaft seal ring is dirty or damaged, contact the dealer (fault code A1).
  • S
    Shawn FrankAug 31, 2025
    How to fix a noisy Adam Pumps PA2 100?
    • K
      Kathleen CuevasSep 1, 2025
      If your Adam Pumps Water Pump is very noisy, cavitation may be the issue; try reducing the negative suction pressure. Also, ensure there are no leaks or restrictions on the suction part. Check for air in the hydraulic circuit and make sure there are no suction leaks. Bleed the air from the circuit by dispensing.
  • K
    Karen PowellNov 15, 2025
    Why is there low or no flow rate from my Adam Pumps Water Pump?
    • A
      Amanda IbarraNov 15, 2025
      If your Adam Pumps Water Pump has low or no flow rate, start by checking the liquid level in the tank and fill it if it's low. Then, inspect the filter and foot valve for dirt or clogs, cleaning or replacing them as needed. Also, look for any damage to the pipe or dispensing nozzle and replace any damaged components. Ensure there are no leaks or restrictions on the suction part. Change the hydraulic discharge configuration to address high pressure drops. Check the bypass valve and clean or replace it if necessary. Inspect and clean the vanes and their housings if they are blocked. Replace excessively worn vanes or the impeller. Make sure the gaskets are properly tightened and not worn. Ensure the power supply voltage matches the rating plate specifications. If problems persist, the motor m...

Summary

Operating Conditions

Power Supply

Details allowed voltage and frequency variations for powering the pump.

Allowed Fluids Forbidden Fluids

Lists compatible and incompatible fluids for pump use.

Installation

Preliminary Checks and Positioning the Pump

Covers pre-installation checks and pump mounting guidelines.

Hydraulic Pipe Connection

Details connecting suction and discharge pipes, including recommended fittings.

Electrical Connection of the Pump

Explains electrical connection for single-phase and three-phase motors.

Intended Use

Troubleshooting

Maintenance

Warranty

Technical Support

Adam Pumps PA2 100 Specifications

General IconGeneral
BrandAdam Pumps
ModelPA2 100
CategoryWater Pump
LanguageEnglish

Related product manuals