1152700 Issue 1 February 2001 Section 2 Operation and Maintenance
Page 2-154
2000, ADC Telecommunications, Inc.
DLP-728
Page 4 of 4
Table 728-1. T3 Performance Monitoring Values
MONTYPE MAX 15-MINUTE
THRESHOLD
COMMENTS
ATM / TC, CONTINUED
In Cells 3695745 A total count of all of the cells that have been received on an interface. This
is for user information and not configurable.
Out Cells 3695745 A total count of all of the cells that have been transmitted out from an
interface. This is for user information and is not configurable.
HEC Viols 3695745 Sets a count of Header Error Checksum violations that the system can incur
before declaring an alert.
OCDs 900 Sets a count of Out of Cell Delineation anomalies that the system can incur
before declaring an alert.