GENERAL INFORMATION
These passive infrared motion detectors are versatile wall-mounted units
employing Fresnel lenses and offering efficient protection patterns for
commercial and residential applications. Best coverage will be obtained if
mounting is selected such that the likely direction of intruder motion is
across the pattern.
When installed per the guidelines, the Split-Zone Optics technology in the
Aurora Series provides reasonable false alarm protection against pets and
other animals up to 40 lbs.
SPECIFICATIONS
Detection Method: Passive Infrared.
Coverage: Pet Immune Lens,
35 ft x 45 ft (10.6m x 13.7m), 90°.
Long Range Lens (optional, Part No. Aurora-LR),
75 ft x 10 ft (23m x 3m).
Detection Zones: Pet Immune Lens - 28 zones.
Long Range Lens - 6 zones,
(optional, Part No. Aurora-LR)
(8 over 8 long range, 8 intermediate, 4 short range).
Pulse Processing: Intermediate, Standard, or Harsh installer selectable.
Note: Use Standard for pet immune applications.
Temp. Compensation: Advanced dual-slope temperature compensation
adjusts for ambients both above and below body
temperature.
Detectable
Walk Rate: 0.5 - 10 ft/Sec (0.15 - 3m/Sec).
Mount Height: 7.0 ft recommended (2.1m).
Indicator: Red LED with enable/disable link.
Alarm Relay: Form A, SPST, 90mA@16VDC,
15-ohm protective resistor.
Input Voltage: 8 - 16VDC (Aurora and Aurora-T).
9-16VDC (Aurora-AT).
(Voltage reversal makes PIR inoperative)
Aurora 10mA 4mA 4mA
Aurora-T 10mA 4mA 4mA
Aurora-AT 10mA 4mA 16mA
All currents nominal at 12VDC.
Standby: Power source should be capable of at least 4
hours of battery standby.
Tamper: Normally closed (with cover on), rated at 0.5A,
30VDC (Aurora-T/Aurora-AT only).
Operating Temp.: 14°F - 122°F (-10°C to +50°C).
Operating
Humidity: Up to 95% RH (max.), non-condensing.
Dimensions: 2.9”W x 4.1”H x 1.5”D (max protrusion)
(60mm x 104mm x 38mm).
Special Instructions
for Installations Containing Pets
To take full advantage of the pet immunity in the Aurora Series, the guide-
lines below should be followed:
Mount the center of the detector 7 ft (2.1m) high.
Set the PIR sensitivity for Standard (STD).
Mount where animals cannot come within six feet of the detector by
climbing on furniture, boxes, or other objects.
Do not aim the detector at stairways that can be climbed by animals.
Note: This unit will provide immunity to false alarms for an individual
animal or a group of animals whose total weight is equal to or less than
40 pounds when the room temperature is above 50°F (10°C).
INSTALLATION
For optimal pet immunity performance, be sure to follow all the guidelines
described in the section “Special Instructions for Installations Containing
Pets.”
A. Normal Surface Mounting
Mount the unit to a firm vertical surface. The wall wiring hole should be no
more than 5/16” (8mm) in diameter.
1. Remove the front cover as shown in Figure 2.
2. Refer to Figure 3. Knockout holes “A” in the base are for normal sur-
face mounting on a wall (remove PC board for full access to holes).
K3119 8/99
AURORA / AURORA-T / AURORA-AT
PASSIVE INFRARED MOTION DETECTORS
®
INSTALLATION INSTRUCTIONS
Current: Model Type w/LED, Alarm w/o LED, Alarm Standby
0
22.5'
22.5'
10'
20' 30' 35'
0
7'
0
10'
20' 30' 35'
SIDE VIEW
TOP VIEW
Figure 1. Protection Patterns
ALTERNATE COUNT POLARITY
EACH ZONE CONSISTS OF 2 FIELDS
0
10 20 30 40 50 60 70 75
5
0
5
0
10 20 30 40 50 60 70 75
0
5
10
SIDE VIEW
TOP VIEW
PET IMMUNE LENS
LONG RANGE LENS
www.PDF-Zoo.com
Question and Answer IconNeed help?

Do you have a question about the ADEMCO Aurora and is the answer not in the manual?

ADEMCO Aurora Specifications

General IconGeneral
Detection Angle90°
TypePIR Motion Detector
CoverageUp to 12m x 12m (40ft x 40ft)
Alarm OutputNormally Closed (NC), 28V DC, 100mA max
Tamper OutputNormally Closed (NC), 28V DC, 100mA max
Detection RangeUp to 12m (40ft)
Field of View90°
MountingWall or corner mounting
CompatibilityADEMCO control panels

Summary

General Information and Specifications

Detection Method

Specifies the passive infrared detection technology used.

Coverage

Defines the detection range and angle for different lenses.

Detection Zones

Details the number and type of detection zones for each lens.

Pulse Processing

Configurable setting for processing infrared signals.

Temperature Compensation

Advanced dual-slope temperature compensation feature.

Detectable Walk Rate

Specifies the minimum and maximum speeds for detection.

Mount Height

Recommended installation height for optimal performance.

Indicator

Describes the function of the LED indicator.

Alarm Relay

Details the specifications of the alarm output relay.

Input Voltage

Specifies the required input voltage range for operation.

Current Draw

Lists current draw for different models and states.

Standby Power Requirement

Requirement for battery standby capability.

Tamper Switch

Details the tamper switch specifications.

Operating Temperature

Defines the operational temperature range.

Operating Humidity

Specifies the maximum allowable humidity.

Dimensions

Provides physical dimensions of the detector unit.

Special Instructions for Pet Immunity

Mounting Height and Sensitivity

Guidelines for mounting height (7 ft) and PIR sensitivity (Standard) for pet immunity.

Mounting Location

Avoid mounting where animals can climb to within six feet of the detector.

Aiming

Do not aim the detector at stairways that can be climbed by animals.

Weight Limit

Immunity to animals up to 40 lbs when room temp is above 50°F.

Installation Procedures

Normal Surface Mounting

Instructions for mounting the unit to a firm vertical surface.

Corner Mounting

Instructions for mounting the detector in a corner of a wall.

Changing Lenses

Procedure for replacing the detector's protective lenses.

Wiring and Configuration

Wiring Connections

Details on connecting wires to the detector's terminals.

LED Enable/Disable Option

Instructions for enabling or disabling the detector's LED indicator.

Pulse Processing Selection

Guidance on selecting the appropriate pulse processing setting.

Testing and Maintenance

Test Procedures

Steps for performing walk-tests and verifying detector operation.

Maintaining Proper Operation

Guidelines for ensuring continuous and correct detector performance.

Troubleshooting

Common issues and remedies for detector malfunctions.

Limitations and Warranty

Limitations of the Detector

Discusses inherent limitations and factors affecting detection performance.

ADEMCO Limited Warranty

Details the warranty terms and conditions for the detector.

Related product manuals