When placing the pump under your bed, be sure to have the ports facing the wall or
facing away from the head of the bed after placing the air cores into the cavity of your new sleep
system. Looking from the foot of your bed, the right side air core will be attached to the right port of
your pump and the left side air core to the left port.
HEAD
FOOT
LEFT
AIR CORE
RIGHT
AIR CORE
WALL
PLACE AIR CORE
HOSES THROUGH
FOAM RAIL
PLACE
INFLATOR
UNDER
THE BED
FRAME
WITH THE
PORTS
FACING
THE WALL.
RIGHT
PORT
LEFT
PORT
CONTROL
PORTS
SUPER QUIET
AIR PUMP CONTROL OPERATION
Adjust-A-Rest®: 2 Wand, 4 Function (Up/Down/Memory/Bed Fill), Dual System
1) Initial Setup Fill & Bed Made Mode: Press and release Bed Fill key. Shortly after releasing Bed Fill key the pump
will begin filling the air chamber. Factory permanent setting is 50 mm/Hg. Repeat step one for the other chamber if
the system is dual. Only one chamber may be filled at a time.
2) Manual Mode: Soft/Deflate or Firm/Inflate keys may be pressed to manually set desired sleep
preference.
3) To Reset Memory For Sleep Preference: Factory preset is 50 mm/Hg. Press Soft/Deflate or Firm/Inflate to
desired level. Press Memory key and hold Memory key until LED readout shows set point for sleep preference. Once
Memory is set, to return to set preference, press and release Memory key twice and pump will adjust chamber
accordingly shortly after second time key is released. Repeat step three for other chamber if system is dual.
4) Pump will stop operating at Memory set point or at 50 mm/Hg or if “hi” is displayed on readout or if pump has
been running continuously for 10 minutes.
5) Energy Efficient Mode: Display lights to turn off 5 minutes after use and relight after any keys are pushed. LED’
s
operate independently - so may not shut off simultaneously.
PLEASE NOTE: While filling chambers it is normal for your Adjust-A-Rest® pump to turn off and on
intermittently as it is allowing pressure to balance between pump and chambers to ensure accurate
support set point readings.
Question and Answer IconNeed help?

Do you have a question about the Adjust-A-Rest SUPER QUIET and is the answer not in the manual?

Summary

Air Pump Operation Modes

Initial Setup and Bed Fill

How to fill the air chamber using the Bed Fill key and factory settings.

Manual Pressure Control

Manually adjust firmness by pressing Soft/Deflate or Firm/Inflate keys.

Saving and Recalling Preferences

Set and recall preferred sleep pressure levels using the Memory key.

Automatic Pump Stop Conditions

Understand when the pump automatically stops operation based on settings or time.

Energy Efficient Display

Learn about the display lights turning off after 5 minutes of inactivity.

Physical Setup and Connections

Air Core Hose Routing

Guide for routing air core hoses through the foam rail of the mattress.

Pump Placement Guidance

Instructions for positioning the pump under the bed frame with ports facing the wall.

Usage Tips and Best Practices

Reducing Vibration and Noise

Use a towel under the pump on hardwood floors to minimize vibration and noise.

Convenient Control Access

Place the wired control in an easily accessible location for both users.

Ensuring Proper Airflow

Uncurl air core hoses and plug the pump into a surge protector for optimal performance and protection.

Secure Hose Connection

How to correctly attach and lock the air hose connector to the pump, avoiding over-tightening.