11
CopyrightADSInstallationManualModelET‐AF‐PDH,Revision3.1,5/25/2017
AccordingtoNSF/ANSI3,section5.19.3and5.19.5
“Thismachinemustbeoperatedwithanautomaticdetergentfeederand,ifapplicable,anautomatic
chemicalsanitizerfeeder,includingavisualmeanstoverifythatdetergentsandsanitizersaredelivered
oravisualoraudiblealarmtosignalifdetergentsandsanitizersare
notavailablefordeliverytothe
respectivewashingandsanitizingsystems.Pleaseseeinstructionsforelectricalandplumbing
connectionslocatedinthismanualandinthefeederequipmentmanual.”
‐‐avisualmeanstoverifythatdetergentsandsanitizersaredelivered;oravisualoraudiblealarmto
signalifdetergentsandsanitizersarenotbeingdeliveredtotherespectivewashingandsanitizing
systems.
ForADSfamilymodelsofET‐AFandthemodelASQ,thechemicalFlowIndicator(084‐6403)isthevisual
meanstoindicateliquidisflowinginthefeedersystemfordetergentandsanitizer.Ineachofthetubes
machinedthroughtheclearplastichousing,thereisablackcoloredmarble(099‐1008).Squeezetube
material(092‐2000)isinsertedinbothupperandlowertubeopenings.Thesetubesarepushedintotheholes
ofthehousingandheldinplacebytensionofthetubewallagainst
thehousing’sinnersurface.When
insertingthesqueezetubesintothehousing,lubricationusingdishsoapishelpful.
Whenthetoptubeoftheindicatorisconnectedtotheinletsideofthechemicalperistalticpump,liquidis
drawnupthroughthesupplytubeofthechemicalbucket.Theliquid
isdrawnintothebottomoftheFlow
Indicatorhousingandliftstheblackindicatormarbleupwardinthevisualchamber.Thismovementshows
flowoftheliquidinthetube.Thetubewithredcoloredliquidwillindicatedetergentflowing,thetubewith
clearliquidwillindicatesanitizer(chlorine)flowing.
Theoperatorshouldbeinformedthatthismovementofthemarblesinthehousingisthevisualindication
thatchemicalsarebeingdeliveredforthewashingandsanitizingoperationsofthedishmachine.
Managementshouldbenotifiedifthereisnomovementoftheindicators.