– 14 –
&KHFNLQJ)RU2SHQ=RQHV
8VLQJWKH>@.H\WR'LVSOD\DQG$QQRXQFH6\VWHP6WDWXV
B
efore arming your system, all protected doors, windows and other protection zones
must be closed or bypassed, otherwise the touchpad will display a "Not Ready" message.
1. Press [
] READY (do not enter code first) to display
faulted zones
.
2. Secure or bypass the zones displayed.
3.
The touchpad’s READY indicator lights when all
protection zones have been either closed or bypassed.
4. Arm the system as desired.
Custom Display:
(-7%61)( 46)77
83 7,3; *%9087
English Display:
Zone no. and “NOT READY”
Voice Status: Voice Touchpads (if installed), can announce system status and faulted
zones (up to 3 zone descriptors) if the Voice Status feature is turned on.
To turn the Voice Status feature on/off:
# + 0 + 2 + 4
(also turns on Voice Chime mode; see
Chime mode
section)
To announce Status: Press [] STATUS key once.
To announce faulted zones: Press the [] STATUS key a second time within 5
seconds of the first press.