EasyManua.ls Logo

ADTEK CPM-10 - Page 9

ADTEK CPM-10
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lo(Low Level Energized):
When the displayed value is lower than the set value
(PV <Set point), the relay action。
Hi(High Level Energized):
When the displayed value is higher than the set value
(PV> Set point), the relay action。
Lo.hld:
(Low Level energized hold Displayed value lower):
than set value action, and continued to maintain
action.
HI.HLD:
(High Level energized hold Displayed value higher):
than the set value, the action, and continued to
maintain action.。
off(Turn off the Relay):
Close relay function when,
relay is off, relay remain open, LED will not
light。
B-8
B-2
B-5
Relay mode LO/HI/LO.HLD/:
HI.HLD/OFF
B-9
B-3
B-6
Relay set point range:
-199.99~299.99
B-11
B-16
B-21
Relay start band 0 00 99.99 (count): . ~
Relay start delay times:
0.00.00~9.59.9( / / . )min sec 0 1s
B-12
B-17
B-22
B-13
B-18
B-23
Relay hysteris 0 00 0 (count): . ~50 0.
B-14
B-19
B-24
Relay delay energize:
0.00.0~9.59.9( / / . )min sec 0 1s
B-15
B-20
B-25
Relay delay de-energize:
0.00.0~9.59.9
( / / . )min sec 0 1s
g r ou p
a o
ANALOGUE
OUTPUT
GROUP
1S back
ENT
P
I a v g
a ) s l
Analogue output
parameter
C-1
A 4 - 2 0
a O t p
Analogue output
type and range:
C-2
) 0 0
a O l s
Analogue output low-
scale
C-3
5 ) 0 0
a O h s
Analogue output hi-
scale:
C-4
) 0 0
a O z o
Analogue output low
fine tunning:
C-5
) 0 0
a O s n
Analogue output Hi
fine tunning:
C-6
P s c l r
Reset fine tunning:
n o n e
C-7
1 1 ) 0 0
a O l t
Output limit:
C-8
8 24/
Engineer level
Parameter Description
Explain
Index
g r o u p
p u l s e
g r o u p
r s 4 8 5
g r o u p
a o
RELAY
GROUP
g r o u p
r e l a y
e n t er
P c o de
NO
YES
ENT
P
ENT
P
1S back
2 2 ) 0
1 0 ) 0
) 0
ANALOGUE
OUTPUT
GROUP
RS485
GROUP
PULSE
GROUP
INPUT
GROUP
g r o u p
i n p u t
Password
P.code
Correct
Default:1000
PV value
V A
W
Press sec escape to measuring page1
Engineer level
En d te rm in al o hm
ADEFGHI -1,:JKL)*MNO.PQNOMRS.<)
*3 4RSTUVWP4W.3
)*1 2 4,1-10~1-27XYZRSP W
)*1 4,1-14/1-1 ~ XYZRSP3W 6 27
)*3 4,1-1 1-1 /1-1 1- /P3W.1 3~ 5 7/1-18/ 20 1-21/1-23/1-24/1-
26/1-27XYZRS
)*3 4,1-1 1- /1- XYZRSP3W.2 7/ 20 23/1-26
)*3 4,1-1 1- /1- XYZRSP3W.3 7/ 20 23/1-26
)*3 4,1-1 1- /1-P4W.1 4~15/ 17~18 20~21/1-23~24/1-26~27
XYZRS
)*+,:1 p 2 w 1 p 3 w 3 p 3 w .1 3 p 3w .2 3p 3w .3/ / / / /
3 p 4 w .1 3 p 4 w .3/
"#$%&':
v a v g. ()*+,-.:
i a v g. ()*/,-.:
f r e q :
2345.
p . t l :()673.
q . t l :()6873.
s . t l :()69:73.
p f . a vg :(),-73;
%45.
v a : )*+.45A
vb :B)*+.45
vc :C)*+.45
ia :A)*/.45
ib :B)*/.45
ic :C)*/.45
p f - a :A)7345.
pf-b :B)7345.
pf-c :C)7345.
p - a :A)7345.
p-b :B)7345.
p-c :C)7345.
q - a :A)87345.
q-b :B)87345.
q-c :C)87345.
s - a :A)9:7345
s - b :B)9:7345
s - c :C)9:7345
RELAY / PULSE output of the outputs can
only choose a functional output
EX: Select PULSE output and then RELAY
function no output and vice versa
Clamp CT
Optional of Clamp CT, make sure
(1)CT of the SN number with the
CPM-10 SN number, as shown
( )2 On the label
A A Phase B B: - ; : -
Phase C C Phase; : - ;
According to the phase matching
Relay Pulse output
CL
BK
AK
AL
BL
CK
, ,0123CT4 56789:; <=>?@A

Related product manuals