61
3.1.2 Primary damper
When you add a new log, the primary damper should be opened until the fire is burning properly. In order to
utilize the fuel to the fullest extent, the embers should have burnt for so long that it is necessary to open the
primary damper for approx. 2 minutes to get the new log to burn.
In order to reduce the risk of ash falling from the stove when the door is opened to add more fuel, it is a good
idea to open the primary damper for approx. 1 minute before the door is opened. This increases the draft
through the stove and reduces the risk that ash will drop on the floor.
3.2 Aduro-tronic
The patent-applied control Aduro-tronic is a manually operated mechanical start-up
device, which works without the use of electricity and automatically regulates the
combustion. All you have to do is put dry wood in the stove and activate the control
system. Aduro-tronic does the rest, leaving you to enjoy the flames, the benefits of
efficient combustion, and a reduced firewood usage up to 40 %. For further
information, go to
www.adurofire.com.
3.2.1 How to operate Aduro-tronic
When lighting with wood only
When lighting a fire in the Aduro H5 for the first time, the maximum amount of
primary air will be needed to light the fire. For that reason, the primary damper
can be kept “forcibly open”. This is done by pulling the primary damper forward
as far as possible and then fixing it with the Aduro Key (see illustration). When
the stove is warm and a layer of embers has been created on the bottom of the
combustion chamber, the Aduro-tronic can be set to the automatic position, i.e.
the Aduro Key can be removed. Alternatively, you can leave the door ajar the
first minutes during lighting the fire (without the key).
When stoking
Each time fresh wood is put in the stove, a precise amount of primary air will be
allowed in for the first few minutes. What’s more important is that the primary air
is not allowed in for too long. This is to ensure optimum combustion. The Aduro-tronic control will ensure
intake of primary air at the right tempo. The automatic is activated by pulling the primary damper out each
time fresh wood is put in the stove. The automatic closes then the primary air gradually.
If you overload the Aduro H5 and burn more than approx. 3,1 kg wood per
hour, there is a risk that the lacquered surface of the stove will become
discolored and eventually fall off. The stove can be repainted, but this is not
covered by the manufacturer’s guarantee. In the same way, any other damage
to the stove caused by overloading will not be covered by the warranty. If the
smoke temperature exceeds 350 degrees, it can damage the gear motor.