Initial Inspection:
1. Visual Inspection: Assess the overall condition of the stove, check for any external damages, and
ensure its installed correctly.
2. Check Seals and Gaskets: Inspect seals and gaskets around the door, glass, and other openings.
3. Check the pellet silo door, to see that it is tight and creates a vacuum when closed. Adjust the
magnets to proper height.
4. Chimney sweeping must be conducted by the local and qualified chimney sweeper. Still it is
recommended to control the smoke pipes, air inlet and smoke outlet for any humidity.
5. The door gaskets are checked using the paper method - a sheet of paper is placed between the
structure and the door. Close the door and pull on the sheet of paper. If the paper comes out easily,
the seal must be adjusted or replaced, if it remains embedded, the seal is still intact.
6. Verify Electrical Components: Test switches, controls, wiring, and connections to ensure they are
functioning correctly and safely.
Cleaning and Maintenance:
1. Follow the cleaning guide on the costumer universe for the given stove: Aduro P1 series -
Cleaning · Customer Self-Service (microsoftcrmportals.com) / Aduro P4 - Cleaning · Customer
Self-Service (microsoftcrmportals.com) Use appropriate tools like a brush and an ash vacuum.
2. Inspect and Clean Venting System: Dismount the stove from the flue. Check the exhaust fan and
clean it, check for blockages, debris, or leaks. Ensure proper airflow for efficient operation.
3. Open both side panels, but do not remove them. Use a can of compressed air or an air blower to
blow away dust inside and on the mechanical and electrical parts in the back part of the stove.
4. On the P4 clean the bottom soot pot on the T - section
Calibration and Testing:
1. Test Sensors and Safety Features: Ensure all sensors and safety features (such as temperature
sensors, pressure switches) are functioning correctly.
2. Calibrate Settings: Adjust settings for optimal performance, including temperature control, pellet feed
rate, and ignition system. Adjustment of settings on Aduro pellet stoves · Customer Self-Service
(microsoftcrmportals.com)
Recommendations and Replacements:
1. Replace Worn Parts: Replace critical components showing signs of wear, such as the igniter,
motors, or gaskets, if necessary.
2. Suggest Improvements: Provide recommendations to the homeowner for improving stove efficiency
or safety, such as using higher-quality pellets or replacing other worn components.
Use only Aduro OEM spare parts.
Restart of the stove:
1. Fill the silo with pellets.
2. Control that the stove ignites correctly in the 1 attempt - of not try adjusting settings and troubleshoot
the problem.
Reset service alarm:
1. Enter the technical settings menu (Password A9)
2. Scroll to “reset par time” and select this option
3. Use the reset password (55)
4. The service timer has been reset