Check that the door is airtight and check that the door gaskets are placed correctly. Tighten the
glass fittings.
Check that the smoke extractor fan and convection fan is working properly.
Check the temperature sensor is mounted correctly on the backside of the smoke extractor fan, and
that it is covered with felt and a metal cover.
Empty the pellet container and vacuum the bottom of the external auger through the opening in the
pellet container, clean any pellet dust that might have accumulated here.
Carefully remove the control board and clean it for dust using compressed air. Check the cables for
damage and that all are connected correctly.