EAGLE PRO CHARGER TROUBLE CODES
RED LEDS BLINKING FORMING STAGE TIMEOUT SHUTDOWN
This indication occurs if the battery voltage has not risen above 1.75 volts per
cell within the first 3 hours of charging. This indicates that a possible battery
problem exists and that the charge cycle has been terminated at this point.
RED LEDS BLINKING OVERALL TIMER SHUTDOWN
This indication occurs if the charger has not completed the charge cycle
within the allowable factory set time period. This indicates that a possible
battery problem exists and that the charge cycle has been terminated at
this point.
RED LEDS BLINKING INTERNAL OVERTEMP SHUTDOWN
This indication occurs if the charger circuitry has detected operating
temperatures inside the charger enclosure that are above factory specified
levels. This could indicate that a possible charger problem exists and that
the charge cycle has been terminated.
RED GREEN LEDS BLINKING BULK STAGE SHUTDOWN
This indication occurs if the battery voltage does not rise properly during
the Bulk Stage. This indicates that a possible battery problem exists and
that the charge cycle has been terminated at this point. Please call
technical support for further assistance (615.471.5300).
RED BLINKING NO BATTERY DETECTED
22