EasyManuals Logo

AEenergy AE8867220PMHRE User Manual

Default Icon
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6.3.2. Rated Capacity (0.2C): 9700mAh (minimum)
The capacity shall be measured at a discharge current of 1940mA (0.2C) and a cut-off voltage of
2.75V after the standard charge (Section 6.3.1.)
6.3.3. High Rate Discharge Capacity (1C): 85% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 9700mA (1.0C) and a cut-off voltage of
2.75V after the standard charge (Section 6.3.1.)
6.3.4. Low Temperature Discharge Capacity (0
o
C): 80% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 1940mA (0.2C) in an ambient
temperature of 0
o
C ±2
o
C and a cut-off voltage of 2.75V after the standard charge (Section 6.3.1.)
6.3.5. Low Temperature Discharge Capacity (-10
o
C): 70% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 1940mA (0.2C) in an ambient
temperature of -10
o
C ±2
o
C and a cut-off voltage of 2.75V after the standard charge (Section 6.3.1.)
6.3.6. High Temperature Discharge Capacity (60
o
C): 100% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 1940mA (0.2C) in an ambient
temperature of 60
o
C ±2
o
C and a cut-off voltage of 2.75V after the standard charge (Section 6.3.1.)
6.3.7. Storage Characteristics (25
o
C)
Capacity Retention: 85% (minimum) of Rated Capacity
Capacity Recovery: 90% (minimum) of Rated Capacity
The capacity retention shall be measured at a discharge current of 1940mA (0.2C) and a cut-off
voltage of 2.75V after standard charge (Section 6.3.1.) and being stored for 28 days at 25
o
C ±5
o
C.
Then, the capacity recovery shall be measured at a discharge current of 1600mA (0.2C) and a
cut-off voltage of 2.75V after standard charge (Section 6.3.1.).
6.3.8. Storage Characteristics (45
o
C)
Capacity Retention : 60% (minimum) of Rated Capacity
Capacity Recovery: 70% (minimum) of Rated Capacity
The capacity retention shall be measured at a discharge current of 1940mA (0.2C) and a cut-off
voltage of 2.75V after standard charge (Section 6.3.1.) and being stored for 28 days at 45
o
C ±5
o
C.Then,
the capacity recovery shall be measured at a discharge current of 1940mA (0.2C) and a cut-off voltage
of 2.75V after standard charge (Section 6.3.1.).
6.3.9. Internal Impedance: 24mΩ max
The internal impedance shall be measured at a since wave alternative current process of 1kHz after
the standard charge.
AEenergy Li Polymer Rechargeable Battery
Product Specifications– AE8867220PMHRE
Specification Number: AE8867220PMHRE -FPS-Spec1 Version 1 Page 6/13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AEenergy AE8867220PMHRE and is the answer not in the manual?

AEenergy AE8867220PMHRE Specifications

General IconGeneral
BrandAEenergy
ModelAE8867220PMHRE
CategoryBattery Charger
LanguageEnglish