6.3.2. Rated Capacity (0.2C): 9700mAh (minimum)
The capacity shall be measured at a discharge current of 1940mA (0.2C) and a cut-off voltage of
2.75V after the standard charge (Section 6.3.1.)
6.3.3. High Rate Discharge Capacity (1C): 85% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 9700mA (1.0C) and a cut-off voltage of
2.75V after the standard charge (Section 6.3.1.)
6.3.4. Low Temperature Discharge Capacity (0
o
C): 80% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 1940mA (0.2C) in an ambient
temperature of 0
o
C ±2
o
C and a cut-off voltage of 2.75V after the standard charge (Section 6.3.1.)
6.3.5. Low Temperature Discharge Capacity (-10
o
C): 70% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 1940mA (0.2C) in an ambient
temperature of -10
o
C ±2
o
C and a cut-off voltage of 2.75V after the standard charge (Section 6.3.1.)
6.3.6. High Temperature Discharge Capacity (60
o
C): 100% (minimum) of Rated Capacity
The capacity shall be measured at a discharge current of 1940mA (0.2C) in an ambient
temperature of 60
o
C ±2
o
C and a cut-off voltage of 2.75V after the standard charge (Section 6.3.1.)
6.3.7. Storage Characteristics (25
o
C)
Capacity Retention: 85% (minimum) of Rated Capacity
Capacity Recovery: 90% (minimum) of Rated Capacity
The capacity retention shall be measured at a discharge current of 1940mA (0.2C) and a cut-off
voltage of 2.75V after standard charge (Section 6.3.1.) and being stored for 28 days at 25
o
C ±5
o
C.
Then, the capacity recovery shall be measured at a discharge current of 1600mA (0.2C) and a
cut-off voltage of 2.75V after standard charge (Section 6.3.1.).
6.3.8. Storage Characteristics (45
o
C)
Capacity Retention : 60% (minimum) of Rated Capacity
Capacity Recovery: 70% (minimum) of Rated Capacity
The capacity retention shall be measured at a discharge current of 1940mA (0.2C) and a cut-off
voltage of 2.75V after standard charge (Section 6.3.1.) and being stored for 28 days at 45
o
C ±5
o
C.Then,
the capacity recovery shall be measured at a discharge current of 1940mA (0.2C) and a cut-off voltage
of 2.75V after standard charge (Section 6.3.1.).
6.3.9. Internal Impedance: 24mΩ max
The internal impedance shall be measured at a since wave alternative current process of 1kHz after
the standard charge.
AEenergy Li Polymer Rechargeable Battery
Product Specifications– AE8867220PMHRE
Specification Number: AE8867220PMHRE -FPS-Spec1 Version 1 Page 6/13