EasyManua.ls Logo

AEG L6FBA51480 - Emergency Drain

AEG L6FBA51480
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.
2
1
8.
2
1
1
WARNING!
Make sure that the impeller of the pump can rotate. If it does not rotate,
contact the Authorised Service Centre. Make sure also that you tighten
the filter correctly to prevent leakages.
14.10 Cleaning the inlet hose
and the valve filter
It is recommended to clean both the
filters of the inlet hose and valve
occasionally to remove any deposit,
collected over the time:
1. Remove the inlet hose from the tap
and clean the filter.
1
2
3
2. Remove the inlet hose from the
appliance by loosening the ring nut.
3. Clean the valve filter on the back of
the appliance with a toothbrush.
4. When you reconnect the hose to the
back of the appliance, turn it left or
right (not in vertical position)
depending on the position of your
water tap.
45°
20°
14.11 Emergency drain
If the appliance cannot drain the water,
carry out the same procedure, described
www.aeg.com30