5. After the filter replacement, press the
Filter Reset alarm button on the control
panel to turn off the alert.
For best performance, place the plastic
housing in the proper location (to the left of
the glass shelf) and replace the air filter every
6 months. For more information refer to "Air
filter change indicator".
The air filter is a consumable accessory
and as such is not covered by the
guarantee.
You can purchase new air filters from
your local dealer.
7.6 Period of non-operation
When the appliance is not in use for long
period, take the following precautions:
1. Disconnect the appliance from electricity
supply.
2. Remove all food.
3. Clean the appliance and all accessories.
4. Leave the doors open to prevent
unpleasant smells.
8. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
8.1 What to do if...
Problem Possible cause Solution
The appliance does not operate. The appliance is switched off. Switch on the appliance.
The mains plug is not connected to
the mains socket correctly.
Connect the mains plug to the
mains socket correctly.
There is no voltage in the mains
socket.
Connect a different electrical appli‐
ance to the mains socket. Contact a
qualified electrician.
The appliance is noisy. The appliance is not supported
properly.
Check if the appliance stands sta‐
ble.
Acoustic or visual alarm is on. The cabinet has been recently
switched on.
Refer to "High temperature alarm"
or "Door open alarm".
The temperature in the appliance is
too high.
Refer to "High temperature alarm"
or "Door open alarm".
The door is left open. Close the door.
The compressor operates continual‐
ly.
Temperature is set incorrectly. Refer to "Control panel" chapter.
ENGLISH 23