6
FUNCTION
The AEM Easy Drum is a low maintenance pre-lter system that provides healthy, clear water, without the user
having to perform daily maintenance. The sophisticated system comes standard with an Amalgam UV-C lamp.
The built-in UV-C Module ensures crystal clear water. The sophisticated design and high quality materials result
in high intensity UV-C radiation with a wavelength of exactly 253.7 nm. The high dose of irradiation kills almost all
bacteria, viruses and fungi and thus provides clear, clean water. The UV-C radiation also keeps the screen panel free
of both biolm and algae growth. This results in optimum performance for clean, healthy water!
With its intelligent electronics the device provides ample warning when the UV-C lamp is no longer producing
enough radiation and therefore needs to be replaced. So you always have a perfectly working unit!
WARNING! Read the entire manual before use/installation of the system!
SAFETY AND INSTALLATION REQUIREMENTS
• See Technical specications for the required mains voltage and current type.
• The device may only be connected to an electrical installation that meets the legal standards. A residual-current
device (30 mA) and earthed wall socket are required. If in doubt, consult a qualied installer.
• Both the Drum Filter and the control box must be installed in a dry, sheltered place. Not in direct sunlight.
• Keep the power plug free from moisture. Prevent water from running along the power lead into the socket.
(See gure 3 for looping of the power lead).
• The device is suitable for fresh water.
• The device is suitable for water temperatures of 4 to 40 °C. If exposed to temperatures outside these limits, the
device must be fully isolated from the water circuit.
• Before commissioning, check the entire device, mains lead and plug for damage. If damage is found, the device
may not be used. Have the damage assessed by the dealer.
• The device may only be switched on when there is sucient water ow.
• Never look directly into the lamp, to prevent any damage to eyes and skin. (The system indicates when replace-
ment of the lamp is desirable).
• When opening the lid/maintenance cover the power to the device/control box must always be switched o.
Warning! The UV-C lamp may still be hot up to ten minutes aer it is switched o.
INSTALLING HIGH PRESSURE PUMP; SEE FIGURE 1
It is important, however, that high-pressure PVC is used for this purpose. The pump generates a pressure of 3 bar.
Pressure peaks of 4 bar may occur during start-up. Therefore do not use sewer & drain PVC.
It is also very important that your Drum Filter is placed at water level. The right point of the water level is shown
in the ow chart on p. 5 The high-pressure pump itself must be placed in a moisture-free location below the water
level.
Never place the high pressure pump directly on the lter oor.
TIP: Place a ball valve between the output (A) and the high pressure pump (B).
1. Place a tee at the output (A) of the lter. Output (A1) of the tee is for the high pressure pump (B). The other (A2)
serves as a passage to the biological lter or pond pump.
2. Connect the line from the output (A) of the tee to the high-pressure pump (B) and then connect the piping of the
high pressure pump (B) to the spray tube (D).