EasyManua.ls Logo

Aeroqual AQM 65 User Manual

Aeroqual AQM 65
127 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MRK-D-0034 V2.0 Aeroqual AQM 65 User Guide Page | 1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Aeroqual AQM 65 and is the answer not in the manual?

Aeroqual AQM 65 Specifications

General IconGeneral
Data LoggingYes
Accuracy (Gas Sensors)±5% of reading
Enclosure RatingIP65
Parameters MeasuredPM2.5, PM10
ConnectivityWi-Fi, Ethernet
Power SupplyRechargeable battery, 12V DC
Data StorageInternal storage
Measurement Range (Gas Sensors)CO: 0-50 ppm
Response Time (Gas Sensors)<60 seconds
Operating Temperature-10°C to 50°C
Operating Humidity0-95% RH (non-condensing)
TechnologyLaser scattering for particulate matter, electrochemical sensors for gases

Summary

Description of AQM 65

Gas Modules

Overview of available gas sensors for the AQM 65.

Particulate matter modules

Details on particulate matter measurement modules including Particle Monitor and Profiler.

Thermal management system

Explains the internal temperature control system and its importance for performance.

Interfacing with Connect and Cloud

How to access and control the instrument using Aeroqual Connect and Cloud.

Quick start guide

Provides essential initial setup and startup instructions for the AQM 65.

Set-up

Unpacking

Initial steps for receiving and unboxing the AQM 65 instrument.

Initial assembly and powering

Crucial steps for basic assembly and first power-on of the AQM 65.

Wire AC mains power and initial start-up

Core procedure for connecting AC power and initiating the AQM 65.

Set up MOXA modem for remote communication

Configuration instructions for the MOXA G3111 HSPA modem for remote access.

Connect Software

Connecting to the AQM 65 for the first time

First interaction with the AQM 65 interface via Wi-Fi access point.

Options for connecting to the AQM 65

Understanding various connectivity choices like Wi-Fi and Ethernet.

Apps for instrument control and calibration

Overview of the core software applications for instrument management.

Manage Data app

Accessing and handling collected data through charts and tables.

Service and Calibration app

Essential tools for instrument upkeep, including service mode and calibration.

User permission types

Managing access levels for Administrator, Engineer, and User roles.

Maintenance and service

Safety requirements

Critical safety information and precautions for handling the AQM 65.

Gas flow meters and flow measurement

Importance and types of flow meters for accurate calibration and maintenance.

Measure and adjust inlet flowrate and module flow rates

Procedures for checking and adjusting gas flow rates for accuracy.

Replace filter on Particle Monitor or Particle Profiler

Step-by-step guide for replacing filters in Particle Monitor and Profiler modules.

Leak check Particle Monitor and Particle Profiler

Essential procedures for checking PM systems for leaks.

Add, remove or replace a gas module

Instructions for changing the configuration of gas modules.

Thermal management system maintenance

Maintenance procedures for the TMS, including cleaning and pressure checks.

Gas module calibration

Calibration frequency

Guidelines for determining the appropriate calibration schedule.

Guidelines for purchasing calibration gas

Recommendations for sourcing calibration gas cylinders and regulators.

Calibration safety

Critical safety measures and considerations during calibration procedures.

Calibration procedure

Step-by-step guide for performing gas module calibration.

Perform the zero calibration

Detailed steps for executing the zero calibration process.

Perform the span calibration

Detailed steps for executing the span calibration process.

Particle Monitor calibration

Factory Servicing

Factory maintenance and calibration schedule for PM modules.

Field Calibration

Procedures and considerations for performing calibration on-site.

Steps to perform a K factor correction

Guide to calculating and applying a K factor for data adjustment.

Appendices

Appendix 1 Troubleshooting

Common problems and solutions for the AQM 65.

Appendix 3 DC Power consumption

Information on the power requirements of the AQM 65.

Appendix 5 Site installation and commissioning

Guidance on proper installation and commissioning of the AQM 65.

Related product manuals