The AFX POWER CAT Series Air Movers are centrifugal air movers, also known as air blowers, snail shells, turbo dryers, or floor fans, designed to produce powerful and focused air movement for rapid drying and air circulation. These units are suitable for light industrial, commercial, and residential applications, offering multifunctional and multipurpose features. The primary intended uses include water damage restoration, flood repair, carpet cleaning, janitorial and sanitation tasks, construction, automotive drying, pet hair drying, and general drying, ventilation, and circulation.
Technical Specifications:
The CAT Series includes three models: CAT 1, CAT 2, and CAT 5, each with varying performance characteristics:
-
CAT 1:
- Motor (HP): 0.2
- Amp: 2
- CFM Area (Sq.Ft.): 0.21
- Rated Airflow (CFM): 1000
- Velocity (Ft./Min): 3390
- RPM (Max): 1000
- Sound dB: 15
- Net Weight (Lbs): 10.5
- Cable Length: 15'
- Cable Gauge: 18
- Temp Control: Yes
- Blade: Plastic
- Fuse: Yes
- Voltage: 110
- Hertz: 60
- Daisy Chain: Yes
- Outlets: 2
-
CAT 2:
- Motor (HP): 0.33
- Amp: 2.5
- CFM Area (Sq.Ft.): 0.276
- Rated Airflow (CFM): 2000
- Velocity (Ft./Min): 3650
- RPM (Max): 1060
- Sound dB: 15
- Net Weight (Lbs): 14
- Cable Length: 15'
- Cable Gauge: 16
- Temp Control: Yes
- Blade: Plastic
- Fuse: Yes
- Voltage: 110
- Hertz: 60
- Daisy Chain: Yes
- Outlets: 2
-
CAT 5:
- Motor (HP): 1.25
- Amp: 7
- CFM Area (Sq.Ft.): 0.43
- Rated Airflow (CFM): 4000
- Velocity (Ft./Min): 3452
- RPM (Max): 1595
- Sound dB: 23
- Net Weight (Lbs): 29
- Cable Length: 13'9"
- Cable Gauge: 18
- Temp Control: Yes
- Blade: Plastic
- Fuse: Yes
- Voltage: 110
- Hertz: 60
- Daisy Chain: No
- Outlets: 1
All models operate on a 110V, 60Hz power supply and feature plastic blades and temperature control.
Usage Features:
The AFX POWER CAT Air Movers are designed for immediate use, requiring no assembly out of the box. To operate, users simply place the unit on the ground with the air vents directed towards the target area, plug it into a grounded outlet, and select the desired speed using the speed control knob. The units offer multiple speeds and can be operated at various angles, providing versatility for different drying and circulation needs.
Key usage features include:
- 3 Speed Operation: Allows users to adjust airflow intensity.
- High Velocity: Delivers powerful air movement for efficient drying.
- Quiet Operation: Designed to minimize noise during use.
- Stackable Design: Enables multiple units to be stacked for easier transport and storage, though precautions should be taken to ensure balance and stability.
- Daisy Chainable (CAT 1 & CAT 2): These models allow multiple units to be connected and powered from a single outlet, enhancing coverage for larger areas. The CAT 5 model is not daisy chainable.
- Portable: Equipped with a handle that also serves as a cord wrap for convenient storage and transport.
- Heavy Duty (CAT 5): The CAT 5 model is built for more demanding tasks.
Safety Instructions:
Users must read and understand the Owner's Manual before using the product to reduce the risk of injury. Important safety precautions include:
- The total amperage of the unit plus any other devices plugged into it must not exceed 12 amps.
- The CAT 5 air mover should not be daisy chained with other units.
- Do not operate the unit near hazardous or dangerous areas, including those with explosive gas, flammables, or heaters.
- Keep children away from the unit.
- Never insert fingers or other objects into the unit.
- Avoid operating the unit in pooled water.
- Prevent the motor from getting wet; if it does, dry it thoroughly before operation.
- Use only a grounded plug or grounded extension cord.
- Do not use the product if the cord shows signs of damage or wear.
- Ensure the power source meets the air mover's requirements.
- Keep all air intake vents free of obstruction.
- Do not remove fixed parts like screens or safety guards.
- Unplug the unit before transporting, cleaning, servicing, or when not in use.
- Do not use aftermarket devices or products with the unit.
- Do not sit or stand on the unit.
- Monitor all units while in use.
- Do not attempt to repair or replace electrical components.
Maintenance Features:
Regular maintenance is crucial for optimal performance and longevity.
- Cleaning: Disconnect the unit from power before any servicing or cleaning. Inspect the unit for damage, blocked inlets and exhausts, and any material buildup. Use a damp cloth to wipe the surface of the housing; never clean with water directly.
- Vibration Check: During operation, inspect the unit for excessive vibration. If excessive vibration occurs (possibly due to the fan wheel rubbing against the roto-molded housing), immediately turn off the unit and contact AFX POWER for inspection by a certified technician.
- Storage: Store the unit in a cool, dry indoor location, out of reach of children, and away from sunlight or excessive moisture. The handle can be used as a cord wrap for neat storage. Units can be stacked for easier transport and storage, but ensure they are balanced and stable.
Troubleshooting:
The manual provides a troubleshooting guide for common issues:
- Air blower does not start: Check power supply, circuit breaker, and ensure the power cord is properly plugged in. If the speed control dial is set to off, turn it to a power setting.
- Decreased air flow: Check for blocked intake or exhaust. Turn off, unplug, let cool down, then remove blockage.
- Unit vibrates excessively or makes odd noises: Fan wheel may be jammed. Turn off, unplug, let cool down, then remove the object jamming the fan wheel.
- Decreased air flow (due to dust/residue): Fan blades may have built up dust or residue. Turn off, unplug, let cool down, then clean or remove the substance from the fan blades.
If these solutions do not resolve the problem, users are advised to contact AFX POWER customer service.
Warranty:
AFX POWER products purchased in North America from authorized distributors come with a one (1) year limited warranty covering defects in materials and workmanship. Users are encouraged to complete online warranty registration before use. The warranty does not cover:
- Consumable parts like power cords or filters.
- Normal wear and tear.
- Problems resulting from external causes (accident, abuse, misuse, electrical power supply issues), unauthorized disassembling or modification, usage not in accordance with product instructions, or lack of necessary maintenance.
For assistance, users can email info@afxpower.com or call AFX POWER U.S. Customer Service Department at 1-877-881-3699, with proof of purchase ready.