Weight | 3.6 kg (7.9 lbs) |
---|---|
Detection Technology | Indirect conversion |
Technology | Digital radiography |
Scintillator | Gadolinium Oxysulfide (Gd2O2S) |
Energy Range | 40 - 150 kV |
Describes the intended purpose of the DR Detector for general radiography applications, excluding mammography.
Specifies the DR Retrofit solution's indication for general projection radiography and exclusion from mammography.
Defines the target audience as trained users who must understand warnings and safety markings.
Explains how the DR Detector integrates with X-ray systems and workstations, covering wired and wireless setups.
Explains the DR Detector Switch in the NX application title bar for monitoring and activating DR Detectors.
Lists safety standards such as EN 60601-1, IEC 60601-1, UL 60601-1, and CAN.CSA-C22.2 No. 601.1.
Describes wireless communication between the DR Detector and NX workstation via access points, compliant with IEEE 802.11n.
Provides instructions for cleaning the exterior of the equipment, including safety warnings and approved cleaning methods.
Outlines the procedure for disinfecting the device using Agfa-approved disinfectants and methods, adhering to regulations.
Lists critical safety directions and warnings for the disinfection process, emphasizing proper handling and ventilation.
Details daily inspection procedures for the detector and cable to ensure safe and proper operation before use.
Provides critical safety instructions for using and handling the DR Detector battery pack and its charger to prevent hazards.
Details essential safety precautions for using power supplies and cords with the equipment to prevent shock and fire hazards.
Outlines safety instructions for the System Control Unit, focusing on ventilation, continuous power, and proper grounding.
Guides users through the initial steps of starting the DR Detector, including battery attachment and power-on procedures.
Explains the fundamental steps for performing a basic X-ray exposure workflow using the DR Detector.
Guides users on registering the DR Detector to different NX workstations for shared use and availability.
Addresses artifacts visible in DR Detector images, their causes, and solutions like calibration.
Troubleshoots issues where the DR detector is not ready for exposure, covering registration and connection problems.
Provides a symptom-cause-remedy guide for various common problems with the detector, charger, and control unit.
Presents detailed technical specifications for the DX-D 40C and DX-D 40G detectors, including electrical, environmental, and dimensional data.