6 Memory
HoldTime: Hold time
DelayTime: Delay time
BaseValue: Pulse base value
NoOfPulse: Number of output pulses for the write operation
DrainMinRng: Minimum range of drain current measurement
[Measurement Parameters]
Drain current Idrain
[User Function]
IdrainPerWg=Idrain/Wg
[Analysis Function]
VthAfter=@L1X (X intercept of Line1)
[X-Y Plot]
X axis: Gate voltage Vgate (LINEAR)
Y1 axis: Drain current Idrain (LINEAR)
Y2 axis: Drain current Idrain (LOG)
[List Display]
Gate voltage Vgate
Drain voltage Vdrain
Drain current Idrain
[Test Contents: Auto Analysis]
Line1: Vertical line for Y1 at Idrain=Id@Vth
[Test Output: X-Y Graph]
X axis: Gate voltage VgateList (LINEAR)
Y1 axis: Drain current before Write operation IdInitialList (LOG)
Y2 axis: Drain current after Write operation IdWrittenList (LOG)
[Test Output: List Display]
Gate voltage VgateList
Drain current before Write operation IdInitialList
Drain current after Write operation IdWrittenList
[Test Output: Parameters]
Threshold voltage before Write operation VthInitial
Threshold voltage after Write operation VthWritten
Agilent EasyEXPERT Application Library Reference, Edition 8