19 WGFMU_IV
19.5 WGFMU Id-Vg pulse (A.05.03.2013.0124_2013.03.26.1)
[Supported Analyzer]
B1500A
[Description]
Measures the drain current vs gate voltage characteristics of MOSFET using WGFMU pulse
[Device Under Test]
MOSFET
[Device Parameters]
Lg: Gate Length
Wg: Gate Width
Temp: Temperature
[Test Parameters]
Period: Pulse period
Drain: WGFMU connected to Drain, secondary sweep voltage output
VdStart: Sweep start voltage of pulse top for Drain
VdStop: Sweep stop voltage of pulse top for Drain
VdStep: Sweep step voltage of pulse top for Drain
VdPulseBase: Pulse base voltage for Drain
VdPulseDelay: Pulse delay for Drain
VdPulseRiseTime: Pulse rise time for Drain
VdPulseWidth: Pulse width for Drain
VdPulseFallTime: Pulse fall time for Drain
Gate: WGFMU connected to Gate, primary sweep voltage output
VgStart: Sweep start voltage of pulse top for Gate
VgStop: Sweep stop voltage of pulse top for Gate
VgStep: Sweep step voltage of pulse top for Gate
VgPulseBase: Pulse base voltage for Gate
VgPulseDelay: Pulse delay for Gate
VgPulseRiseTime: Pulse rise time for Gate
VgPulseWidth: Pulse width for Gate
VgPulseFallTime: Pulse fall time for Gate
MeasRange: Measurement range for drain current
Hold: Hold Time
MeasDelay: Measurement delay time
AveragingTime: Measurement averaging time
[Extended Test Parameters]
DataDisplay_PatternValidation : PatternValidation data display mode (Not effective for Pattern Validation
mode)
Disable (does not display PatternValidation data during measurement)
Enable_Waveform_MeasTiming (displays Waveform and MeasTiming during measurement)
ExecutionMode: Execution mode
Run Vector: Performs the waveform output and measurement
Pattern Validation: Displays the waveform and measurement
Agilent EasyEXPERT Application Library Reference, Edition 8
19-10