Copilot flight controls (if installed) : Condition and security.
Landing gear lever lock : Check in NORMAL position
and lockwired.
Lower and lateral transparent panels
: Cleanliness and integrity.
Copilot door : Security. Sliding window
closed, if installed.
BATT RELAY circuit breaker : In.
NOTE
The above mentioned circuit breaker is accessible from the pilot
pedal bay and thus cannot be seen from the on-board seated position.
CVDR TEST (if installed)
BATT : ON.
FDR and CVR fault lights : After 5 seconds, check both
lights go off.
CVDR test : Press and hold TEST switch on
the CVDR control panel for at
least 5 seconds.
Check green lamp TEST stays
on (the TEST lamp stays on as
long as the TEST button is
pressed).
BATT : OFF.
Pilot door : Security. Sliding window
closed, if installed
Pilot door jettison handle and relevant
safety latch : Correct position.
Pilot safety belt and inertia reel : Condition.
RFM A109E
2-12 E.A.S.A. Approved
Rev. 41