CAUTION
Avoid to operate the ENG MODE switches simultaneously.
Gas producer (N1) : Note increasing and START
legend vertically displayed.
Engine Temperature (TOT) : Note increasing and IGN leg-
end vertically displayed.
CAUTION
Monitor engine start and if any of the following occurs:
- lightup is not obtained within 10 seconds of fuel on
- abnormal noises are heard
- TOT increases beyond start limit
- N1 or N2 increases beyond engine limits
- engine hangs (stagnation in N1 below 54%)
shutdown the engine by setting OFF the pertinent ENG MODE
switch.
CAUTION
Following aborted start shutdown perform the following proce-
dure before restarting:
- Allow 30 seconds fuel drain period
- Perform a 30 seconds DRY MOTORING RUN.
Refer to Section 1 for engine starter limitations and to DRY
MOTORING RUN procedure in this Section.
Engine oil pressure : Check.
RFM A109E