CAUTION
Do not attempt to restart the engine.
SMOKE IN CABIN, TOXIC FUMES, ETC.
In case of smoke, toxic fumes, etc., proceed as follows:
VENT CKPT switch : HIGH.
VENT CAB switch (if installed) : HIGH.
Front ventilation ports : Open.
Sliding window (if installed) : Open.
If smoke persists:
Airspeed : Reduce to minimum.
Cabin doors : Jettison.
CAUTION
Jettison the cabin doors at low forward speed and low rate of
descent to prevent possibility of doors to hit tail rotor or main
rotor.
NOTE
If smoke is suspected to be of an electrical origin, attempt to
isolate the source by switching OFF electrical circuits.
Land as soon as possible.
RFM A109E
3-58 R.A.I. Approved
Rev. 11