SECTION 3 - EMERGENCY AND MALFUNCTION
PROCEDURES
(E.M.S. P/N 109-0811-70-119/-165, -137/173 and -143)
WARNING SYSTEM
CAUTION MESSAGES (YELLOW)
NOTE
The messages UTIL DOOR and OXYGEN CLOSED are respec-
tively replaced by caution and advisory lights on the instrument
panel when IDS configuration utilizes the EDU software version
06 or lower and DAU software version 05 or lower.
EDU message Fault condition Corrective action
UTIL DOOR The utility access door
to the oxygen bottle
socket is not correctly
closed.
Close door correctly before
flight.
If the caution message is
displayed during flight,
land as soon as practicable.
In emergency, pilot(s) must manually close the shut-off valve of the oxygen
supply system by pushing the OXYGEN MANUAL SHUT-OFF handle on the
overhead panel (green OXYGEN CLOSED advisory message on EDU 2
displayed).
EVACUATION THROUGH EMERGENCY EXITS
Unstrap the patient(s) and evacuate either through the LH or RH emergency
exit.