Global LF Series Pure Sine Wave Inverter Charger
User’s Manual
Version 9.0
PICOGLF10W-PICOGLF60W

Questions and Answers

Summary

Important Safety Information

General Safety Precautions

General safety guidelines to prevent hazards like fire, shock, and overheating. Includes ventilation requirements.

Battery Safety Precautions

Safety measures to prevent explosions, burns, and injuries when handling batteries.

Introduction

General Information and Applications

Overview of the Global LF Series Inverter Charger, its features, and application areas.

Features

Electrical Performance

Inverter Operation

Details the inverter's topology, operation modes, and output characteristics like sine wave quality.

AC Charger

Power Transfer Modes

Swift Power Transfer

Describes the rapid transfer time between inverter and AC modes, akin to a UPS.

Synchronized Power Transfer

Explains the synchronized transfer process to minimize load interruption and protect sources.

Transfer Delay

Details the 15-second delay for generator spin-up and stable voltage/frequency.

Auto Frequency Adjust

Power Saver Function

Protections

Remote Control Options

LED Indicator Lights;Status

Audible Alarms and Fan Operation

DIP Switches Configuration

Low Battery Trip Volt (SW1)

Explains how to set the low battery voltage disconnection point using SW1.

AC Input Range (SW2)

Describes setting the AC input voltage range for different loads using SW2.

DIP Switch Functions

Power Saver Override (SW3)

How to enable or disable the power saver detection pulse using SW3.

Frequency Switch (SW4)

Setting the output frequency to 50Hz or 60Hz using SW4.

AC;Battery Priority (SW5)

Configuring the priority between AC input and battery power using SW5.

Auto Generator Start

Other Features

Battery Temperature Sensing

How the battery temperature sensor adjusts charging voltage for optimal performance.

Battery Voltage Recovery

How the inverter restarts after low battery shutoff.

Conformal Coating

Details the protective coating applied to the PCB for resistance to elements.

Automatic Voltage Regulation

Describes the AVR function for stabilizing input AC voltage and UPS functionality.

Installation

Unpacking and Initial Inspection

Steps for unpacking the inverter and verifying included items.

Location and Wiring

Location Requirements

Guidelines for choosing a suitable installation location, considering environmental factors.

Installation Tools and Materials

Lists necessary tools and materials for installing the inverter and sensor.

DC Wiring Guidelines

Recommendations for DC wiring, cable size, and placement to minimize voltage drop.

Reducing RF Interference

Battery Cable Inductance Reduction

Method to reduce inductance of battery cables to minimize induced voltages.

AC Wiring

AC Wiring Model Confirmation

Critical instruction to verify the inverter model before proceeding with AC wiring.

Grounding

Automatic Neutral-to-Ground Connection

Explains the automatic connection/disconnection of AC neutral to ground in different modes.

Disabling Auto Neutral-to-Ground

Describes how to disable the automatic neutral-to-ground bond if required by installation.

Install Flange

Troubleshooting Guide

Indicator and Alarm Status

Chart detailing LED indicators and alarms for various operational statuses and faults.

Warranty

Warranty and Support Information

Details warranty coverage, exclusions, and contact information for support.

Specifications

Appendix 1 - Circuit Schematics

Appendix 2 - Installation Diagram

Summary

Important Safety Information

General Safety Precautions

General safety guidelines to prevent hazards like fire, shock, and overheating. Includes ventilation requirements.

Battery Safety Precautions

Safety measures to prevent explosions, burns, and injuries when handling batteries.

Introduction

General Information and Applications

Overview of the Global LF Series Inverter Charger, its features, and application areas.

Features

Electrical Performance

Inverter Operation

Details the inverter's topology, operation modes, and output characteristics like sine wave quality.

AC Charger

Power Transfer Modes

Swift Power Transfer

Describes the rapid transfer time between inverter and AC modes, akin to a UPS.

Synchronized Power Transfer

Explains the synchronized transfer process to minimize load interruption and protect sources.

Transfer Delay

Details the 15-second delay for generator spin-up and stable voltage/frequency.

Auto Frequency Adjust

Power Saver Function

Protections

Remote Control Options

LED Indicator Lights;Status

Audible Alarms and Fan Operation

DIP Switches Configuration

Low Battery Trip Volt (SW1)

Explains how to set the low battery voltage disconnection point using SW1.

AC Input Range (SW2)

Describes setting the AC input voltage range for different loads using SW2.

DIP Switch Functions

Power Saver Override (SW3)

How to enable or disable the power saver detection pulse using SW3.

Frequency Switch (SW4)

Setting the output frequency to 50Hz or 60Hz using SW4.

AC;Battery Priority (SW5)

Configuring the priority between AC input and battery power using SW5.

Auto Generator Start

Other Features

Battery Temperature Sensing

How the battery temperature sensor adjusts charging voltage for optimal performance.

Battery Voltage Recovery

How the inverter restarts after low battery shutoff.

Conformal Coating

Details the protective coating applied to the PCB for resistance to elements.

Automatic Voltage Regulation

Describes the AVR function for stabilizing input AC voltage and UPS functionality.

Installation

Unpacking and Initial Inspection

Steps for unpacking the inverter and verifying included items.

Location and Wiring

Location Requirements

Guidelines for choosing a suitable installation location, considering environmental factors.

Installation Tools and Materials

Lists necessary tools and materials for installing the inverter and sensor.

DC Wiring Guidelines

Recommendations for DC wiring, cable size, and placement to minimize voltage drop.

Reducing RF Interference

Battery Cable Inductance Reduction

Method to reduce inductance of battery cables to minimize induced voltages.

AC Wiring

AC Wiring Model Confirmation

Critical instruction to verify the inverter model before proceeding with AC wiring.

Grounding

Automatic Neutral-to-Ground Connection

Explains the automatic connection/disconnection of AC neutral to ground in different modes.

Disabling Auto Neutral-to-Ground

Describes how to disable the automatic neutral-to-ground bond if required by installation.

Install Flange

Troubleshooting Guide

Indicator and Alarm Status

Chart detailing LED indicators and alarms for various operational statuses and faults.

Warranty

Warranty and Support Information

Details warranty coverage, exclusions, and contact information for support.