(NH-1SA, NH-2SA, NHR-SP, NHR-3TS
The sub station flush-mounts in 2-
As shown terminate connector wires to the Trunk line with wire nuts, and plug into the socket
It is recommended to use a junction box to divide 3P trunk line to each Sub station
ether, i.e. Trunk line in & out cables and the cable
ang box of Corridor lamp or 2-gang box for NHR-3TS
Wire nuts
Extension
cable
6-pin plug
To: CN1
on sub
(any)
To:3P sub
trunk lin
Splice 2 wires with wire-nuts,
securely protecting from being
pulled or crushed.
Cover
Screws(4)
2-gang box
Box must be more than 2" (50mm) deep.
3-5/16"
(83.5mm)
(NH-2SA/A in this illustration)
SINGLE-GANG-BOX
for corridor lamp
3P sub trunk
outgoing cable
3P sub trunk
incoming cable
Separate cable for
lamp (3 cond.)
Splice three cables
together with wire nuts
To: NH-1SA or NH-2SA
bedside sub station
NHR-3TS
3P sub trunk
outgoing cable
3P sub trunk
incoming cable
Splice three cables
together with wire nut
6 lead-wires from
6-pin connector
(2-gang box)
- CAUTION: THE TOTAL SYSTEM CHASSIS RISK CURRENT SHOULD NOT EXCEED 500µA
ub station back case dimensions