EasyManua.ls Logo

Aiphone DA-1MD - User Manual

Aiphone DA-1MD
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PRECAUTIONS
(5
General
Prohibition
s
(^)
Prohibitions
to
subject
the
unit
to
water
(^)
Prohibitions
to
dismantle
the
unit
/?\
WARNING
(Negligence
could
result
in
death
or
serious
injury
to
people.)
1.
This
device
is
electrical.
Wiring
must
be
done
by
qualified
personnel.
(*\)
2.
Do
not
dismantle
or
alter
the
unit.
Fire
or
electric
shock
could
result.
3.
Do
not
open
the
unit
case.
^
4.
Keep
the
unit
away
from
water
or
any
other
liquid.
Fire
or
electric
shock
could
result.^)
5.
Do
not
put
any
metal
into
the
unit
through
openings.
Fire,
electric
shock
or
unit
trouble
could
result.^
6.
PT-1211C,
D,
DR
shall
be
used
for
DA-1MD
system
only,
and
never
for
other
devices.^)
/i\
CAUTION
(Negligence
could
result
in
injury
to
people
or
damage
to
property.)
1.
Mount
the
unit
on
wall
in
a
convenient
location,
but
not
where
it
could
be
bumped
or
jarred.
Injury
could
result.
0
2.
Do
not
manually
hold
down
hook
switch
to
verify
chime
volume.
It
sounds
very
loud
near
your
ears
and
can
cause
your
hearing
damage.
(5)
3.
In
case
of
electrical
storms,
unplug
power
supply
from
AC
outlet.
Fire
or
electric
shock
could
result.
(\)
4.
Do
not
install
the
unit
in
any
of
the
following
locations,
as
it
may
cause
the
system
to
malfunction;
High
or
extreme
cold
temperature
area:
under
direct
sunlight,
near
equipment
that
varies
in
temperature,
in
front
of
air-conditoner,
inside
a
refrigerated
area,
etc.
Places
subject
to
moisture
or
humidity
extremes,
such
as
bathroom,
cellar,
greenhouse,
etc.
(§)
Places
subject
to
environmental
conditions,
such
as
dust,
oil,
chemicals,
salt,
etc.
Places
subject
to
constant
vibration
or
impact.
Places
subject
to
steam
or
smoke,
such
as
near
heating
appliances,
cooking
surface,
etc.
GENERAL
PRECAUTIONS
1.
in
areas
where
broadcasting
station
antennas
are
close
by,
intercom
system
may
be
affected
by
radio
frequency
interference.
2.
The
system
is
not
operational
during
a
power
failure.
FK0957
0702
B

Other manuals for Aiphone DA-1MD

Question and Answer IconNeed help?

Do you have a question about the Aiphone DA-1MD and is the answer not in the manual?

Summary

Precautions

Warning

General warnings regarding death or serious injury due to improper use of the electrical device.

Caution

Precautions to prevent injury to people or damage to property from system malfunction.

General Precautions

Advice on potential interference and system operation during power outages.

Names and Functions

Component Identification

Identifies and describes the functions of each button and indicator on the DA-1MD unit.

Operations

Operating Procedures

Illustrates the steps for calling, communicating, and releasing the door lock.

Technical Precautions

Ambient Temperature

Specifies the operating temperature range for the DA-1MD unit.

Repair and Cleaning

Guidance on seeking professional repair and safe cleaning methods for the unit.

Specifications

Technical Specifications

Details power source, dimensions, and weight of the DA-1MD unit.

Warranty

Summary

Precautions

Warning

General warnings regarding death or serious injury due to improper use of the electrical device.

Caution

Precautions to prevent injury to people or damage to property from system malfunction.

General Precautions

Advice on potential interference and system operation during power outages.

Names and Functions

Component Identification

Identifies and describes the functions of each button and indicator on the DA-1MD unit.

Operations

Operating Procedures

Illustrates the steps for calling, communicating, and releasing the door lock.

Technical Precautions

Ambient Temperature

Specifies the operating temperature range for the DA-1MD unit.

Repair and Cleaning

Guidance on seeking professional repair and safe cleaning methods for the unit.

Specifications

Technical Specifications

Details power source, dimensions, and weight of the DA-1MD unit.

Warranty

Overview

The Aiphone DA-1MD is a two-wire electric lock door phone designed for residential or small office applications, providing basic communication and door release functionality.

Function Description

The DA-1MD serves as an indoor station for an intercom system, allowing occupants to communicate with visitors at the door and remotely unlock an electric door lock. Its primary functions include:

  • Call Reception: When a visitor presses the call button at the door station, the DA-1MD rings to alert the occupant.
  • Two-Way Communication: After lifting the handset, the occupant can engage in a two-way conversation with the visitor.
  • Door Release: A dedicated "DOOR RELEASE" button allows the occupant to remotely unlock an electric door lock, granting access to the visitor.
  • Service Button (Option): An additional "SERVICE" button is available for optional functions, though its specific use is not detailed in this manual.
  • Call Tone Control: The unit features a call tone volume control, allowing users to adjust the loudness of the incoming call ring. An LED indicator lights up when the volume is set to the "MUTED" position, indicating that the call tone is off.

Important Technical Specifications

  • Power Source: The unit operates on AC 15V, which is supplied from a separate power supply unit (not included with the DA-1MD itself).
  • Ambient Temperature: The DA-1MD is designed to operate within a temperature range of 0°C to +40°C (32°F to 104°F).
  • Dimensions: The physical dimensions of the unit are 200mm (H) x 89mm (W) x 63mm (D), which translates to approximately 7-7/8 inches (H) x 3-1/2 inches (W) x 2-1/2 inches (D).
  • Weight: The unit weighs approximately 350g (0.77 lbs).
  • System Compatibility: The DA-1MD is specifically designed for use with the PT-1211C, D, or DR system components. Using it with other devices is explicitly prohibited.
  • Wiring: This is a two-wire system, and all wiring must be performed by qualified personnel due to its electrical nature.

Usage Features

The DA-1MD is designed for straightforward operation:

  • Calling: To initiate a call (presumably to the door station, though the manual describes receiving calls), the user would depress and hold down the call button.
  • Answering: When the call tone rings, the user lifts the handset to communicate with the visitor.
  • Door Release: During communication, pressing the "DOOR RELEASE" button activates the electric door release mechanism.
  • Call Tone Volume Adjustment: A slide control allows the user to adjust the call tone volume from "MUTED" (off) to "MID" or "HIGH." The "Call tone off LED" illuminates when the volume is in the "MUTED" position.
  • Mounting: The unit should be mounted on a wall in a convenient location where it is unlikely to be bumped or jarred, to prevent injury.

Maintenance Features

  • Cleaning: The unit can be cleaned with a soft cloth dampened with a neutral household cleanser. Abrasive cleaners or cloths should not be used.
  • Repairs: In case of malfunction, the manual advises seeking a qualified technician for repairs. The warranty covers bench repairs only, and any repairs must be made at a shop or place designated in writing by Aiphone. On-site service calls are not covered by the warranty.

Important Precautions and Warnings

The manual emphasizes several critical safety and operational precautions:

  • Electrical Safety: The device is electrical, and all wiring must be done by qualified personnel. Users are warned against dismantling, altering, or opening the unit's case, as this could lead to fire or electric shock.
  • Water and Metal: The unit must be kept away from water or any other liquid to prevent fire or electric shock. No metal objects should be inserted into the unit's openings, as this could cause fire, electric shock, or unit malfunction.
  • System Compatibility: Only PT-1211C, D, or DR components should be used with the DA-1MD system.
  • Hearing Protection: Users are cautioned against manually holding down the hook switch to verify chime volume, as the sound can be very loud near the ears and cause hearing damage.
  • Environmental Conditions: The unit should not be installed in locations subject to extreme temperatures (direct sunlight, near temperature-varying equipment, air conditioners, refrigerated areas), high moisture or humidity (bathrooms, cellars, greenhouses), harsh environmental conditions (dust, oil, chemicals, salt), constant vibration or impact, or near steam/smoke sources (heating appliances, cooking surfaces). These conditions can cause the system to malfunction.
  • Power Surges: During electrical storms, the power supply should be unplugged from the AC outlet to prevent fire or electric shock.
  • Power Failure: The system is not operational during a power failure.
  • Radio Frequency Interference: In areas close to broadcasting station antennas, the intercom system may experience radio frequency interference.

Warranty Information

Aiphone provides a one-year warranty covering defects in material and workmanship under normal use and service. The warranty covers free repair or replacement if the product is found to be defective upon examination. Aiphone reserves the right to make the final decision regarding defects and warranty coverage. The warranty does not cover misuse, neglect, accident, use in violation of instructions, repairs or alterations performed outside the factory, batteries, or damage caused by batteries. It covers bench repairs only, and Aiphone is not responsible for on-site service call costs.

Aiphone DA-1MD Specifications

General IconGeneral
BrandAiphone
ModelDA-1MD
CategoryIntercom System
LanguageEnglish

Related product manuals