Complaint:
UNIT DOES NOT FULLY REPRESSURIZE:
BACK PRESSURE IN REGENERATING TOWER:
INLET OR EXHAUST VALVES NOT FUNCTIONING:
NOTES:
Possible Cause & Repair:
- Purge rate too low: Adjust purge.
- Exhaust valves leaking: See above.
- Purge or repressurization orifice plugged: Clean
- Clogged mufflers: Clean, repair or replace.
- Check valves leaking: Clean, repair or replace.
- Purge flow too high: Adjust.
- Leaking inlet valve: See inlet valve not function-
ing.
- Bad seals or solenoid: Rebuild valves with
available kits or replace
- No output from controller: Replace fuse or
controller
- Valve dirty: Clean.
- When factory assistance is required always
provide model, serial number, full description of
problem and a completed analyzing chart.
- For trouble shooting PowerLoc, please consult
PowerLoc manual.
If at any time a problem develops, fill out a copy of
the analyzing chart. It is also good practice to fill out
a chart monthly. Keep these charts on file for
comparison purposes if a problem arises.