16. A. Sequence of Operation Diagram
RECOMMENDED INSTALLATION
CLEAN DRY, CONTAMINANT FREE AIR
(Note: Desiccant Dryers are designed to remove water VAPOR only)
(Liquid water and oil will damage desiccant)
WARNING: INCORRECT INSTALLATION WILL VOID WARRANTY
- COALESCING PREFILTER W/ AUTO DRAIN MUST BE INSTALLED
- DRYERS ARE DESIGNED FOR 100ºF INLET TEMPERATURE
- DRYER SHOULD BE LOCATED IN AN AREA ACCESSIBLE FOR MAINTENANCE
- AMBIENT TEMP. SHOULD BE BETWEEN 35ºF & 100ºF
- LOCATION SHOULD BE CLEAN, COOL, w/ A LEVEL, VIBRATION FREE FLOOR.
KEY:
AD = AUTOMATIC DRAIN
F = PARTICULATE FILTER
C = COALESCING FILTER
A = ADSORBING FILTER
T = TEMPERATURE INDICATOR
D = DEWPOINT INDICATOR/CONTROLLER
= DIFFERENTIAL PRESSURE INDICATOR
DWG AT718
Rev. C
1/15/92
NOTES:
1.By-Pass Piping should be installed around filters and dryer
for servicing.
2.Differential pressure indicators should be installed on filters
for monitoring of elements
3.Coalescing Prefilter & Particulate Afterfilter are required.
Particulate filter before dryer and adsorber after dryer are
optional.
4.Auto drains must be installed on separator, air receiver,
prefilter & coalescer.
5.Location of receiver may vary depending on particular
conditions & type of compressor. Auto drain required when
receiver is mounted upstream of dryer.
6.Locate coalescing filter as close to dryer as possible.