Do you have a question about the Airwell AWAU-YBZ318-H11 and is the answer not in the manual?
Cooling Capacity | 18000 BTU/h |
---|---|
Heating Capacity | 19000 BTU/h |
Energy Efficiency Ratio (EER) | 3.21 |
Seasonal Energy Efficiency Ratio (SEER) | 6.1 |
Power Supply | 220-240V, 50Hz |
Noise Level (Indoor) | 42 dB(A) |
Air Flow (Indoor Unit) | 850 m³/h |
Type | Split System |
General overview of the YBZ DC inverter multisplit outdoor unit.
Key technological innovations and benefits of the multi-split inverter unit.
Description of the wall-mounted indoor unit and its components.
Details on the microprocessor indoor controller and remote control.
Information on outdoor unit installation, protection, and components.
Details on flare type interconnecting tubing for site production.
Information on the manuals supplied with each unit.
Tables showing compatible indoor and outdoor unit combinations.
Tables detailing various indoor unit combinations for different outdoor models.
Technical specifications and characteristics for the YBZ214 outdoor unit.
Technical specifications and characteristics for the YBZ318 outdoor unit.
Technical specifications for HZD/HYD009 indoor units.
Technical specifications for HZD/HYD012 indoor units.
Technical specifications for HZD/HYD018 indoor units.
Standard rating conditions for cooling and heating operations.
Defines the operating limits for cooling and heating modes.
Dimensional drawings for specific indoor unit models.
Dimensional drawings for HZD018 and HYD018 indoor units.
Dimensional drawings for the YBZ214 outdoor unit.
Dimensional drawings for YBZ318 and YBZ430 outdoor units.
Cooling capacity data and correction factors for YBZ214.
Heating capacity data and correction factors for YBZ214.
Cooling capacity data and correction factors for YBZ318.
Heating capacity data and correction factors for YBZ318.
Cooling capacity data and correction factors for YBZ430.
Heating capacity data and correction factors for YBZ430.
Pressure curves (suction, discharge, input current) for YBZ214 cooling.
Pressure curves (suction, discharge, input current) for YBZ214 heating.
Pressure curves (suction, discharge, input current) for YBZ318 cooling.
Pressure curves (suction, discharge, input current) for YBZ318 heating.
Pressure curves (suction, discharge, input current) for YBZ430 cooling.
Pressure curves (suction, discharge, input current) for YBZ430 heating.
Methodologies for measuring sound pressure level.
Sound pressure level spectrum charts for various indoor units.
Electrical data including power supply, current, and wiring for models.
Wiring diagrams for specific indoor unit models.
Wiring diagrams for HZD018 and HYD018 indoor units.
Wiring diagram for the YBZ214 outdoor unit.
Wiring diagram for the YBZ318 outdoor unit.
Wiring diagram for the YBZ430 outdoor unit.
Shows the wiring connections between indoor and outdoor units.
Refrigeration cycle diagram for multi-split systems.
Information on tubing connections, bending, and torque specifications.
Overview of electronic control system and abbreviations used.
Controls and settings for compressor frequency.
Details on indoor and outdoor fan speed settings and control.
Electronic Expansion Valve (EEV) and Reversing Valve (RV) control.
Details on Fan, Cool, Heat, Dry, and 8 Degree Heat modes.
Overview of protection codes, mode conflicts, and fault handling.
How to operate the unit and interpret its indicators.
Procedures for installation tests, forced deicing, and forced mode.
Safety precautions for electrical and control system troubleshooting.
Interpretation of fault codes displayed by ODU LEDs and IDU segments.
Procedures for checking refrigeration system and main components.
Resistance-temperature chart for Room/Outdoor Air Temperature sensors.
Resistance-temperature charts for Indoor/Outdoor Coil/Return Gas sensors.
Resistance-temperature chart for Compressor Top Temperature sensor.
Exploded view diagram for HYD009-012 indoor units.
List of spare parts for the HYD009 indoor unit.
List of spare parts for the HYD012 indoor unit.
List of spare parts for the HZD009 indoor unit.
List of spare parts for the HZD012 indoor unit.
Exploded view diagram for HYD018, HZD018 indoor units.
List of spare parts for the HYD018 indoor unit.
List of spare parts for the HZD018 indoor unit.
Exploded view diagram for the YBZ214 outdoor unit.
List of spare parts for the YBZ214 outdoor unit.
Exploded view diagram for the YBZ318 outdoor unit.
List of spare parts for the YBZ318 outdoor unit.
Exploded view diagram for the YBZ430 outdoor unit.
List of spare parts for the YBZ430 outdoor unit.