VIDEO SECTION - 2
SPEC.
8. Color Phase Equipment: Video Analyser (Expect VM700) YEL.=167.6°
Test Signal: LT2-1,1-1, SMPTE Color Bar CYAN=283.5°
Test Point: Complex or S(C) Output GRN.=240.6°
Method: 1. Connect TP to Video Analyser MAG.=60.6°
2. Test Phase of Various Colors in Color Bar. RED=103.5°
BLU.=347.6°
within+9°/-1°
9. RGB Output Equipment: Waveform Monitor 700-70/+105mV
(only for w/RGB Model) Test Signal: LT2-1,1-1, SMPTE Color Bar
Test Point: RGB Output
Method: 1.Connect TP to Waveform Monitor
2. Convert to RGB Output Mode
3. Play Test Disc Signal Portion and Test
100IRE (100% Whirt) Output Level.
10. Sub Carrier Frequency Equipment: Video Analyser (Expect VM700) or NTSC=
Spectral Analyser 3579545±160Hz
Test Signal: LT2-1,1-1, SMPTE Color Bar
Test Point: Complex or S(C) Output
Method: 1. Connect TP to Video Analyser PAL=
2. Play Test Disc Signal Portion and Test Sub 4433619±200Hz
Carrier Frequency.
NOTE: Test Data After Power ON 25~35 Seconds.
REMARK: 1. The initial picture of TV shape is 4:3 Normal.
2. Black level is Enhanced.
3. Audio output select is Analog 2CH.
TEST CONDITIONS
VIDEO SECTION - 1
SPEC.
1. Video Level Equipment: Waveform Monitor (Except VM700) 714-71/+107 mV
Test Signal: LT2-1,1-1, SAMPTE Color Bar
Test Point: Complex or S(Y) Output
Method: 1. Connect TP to Waveform Monitor
2. Play Test Disc and Test Output Level from
Pdestal of H display to 100IRE
(S Terminal without Load When Test complex Output)
2. SYNC Level Equipment: Waveform Monitor (Except VM700) 286-29/+43 mV
Test Signal: LT2-1,1-1, SAMPTE Color Bar
Test Point: Complex or S(Y) Output
Method: 1. Connect TP to Waveform Monitor
2. Play Test Disc and Test SYNC Signal
(S Terminal without Load When Test Complex Output)
3. Chroma Burst Level Equipment: Waveform Monitor (Except VM700) 286-29/+43 mV
C-BURST Test Signal: LT2-1,1-1, SAMPTE Color Bar
Test Point: Complex or S(Y) Output
Method: 1. Connect TP to Waveform Monitor
2. Play Test Disc and Test Chroma Burst Level
(S Terminal without Load When Test Complex Output)
4. Chromatism Signal Equipment: Waveform Monitor (VM700) Y=714-71/+107mV
Output Level Test Signal: LT2-1,1-1, SAMPTE Color Bar SYNC=286-29/+43mV
Test Point: Chromatism Output (Y/CB/CR) CB,CR=
Method: 1.Connect TP to Waveform Monitor 525-53/+79mV
2. Play Test Disc and Test Output Level and B-Y=286-29/+43mV
PP Value of CB,CR R-Y=286-29/+43mV
5. Frequency Response Equipment: Waveform Monitor (VM700)
Test Signal: LT2-1,1-1, Multi Burst 0.5MHz=0dB
Test Point: Complex or S(Y) Output 2MHz=0±1.0dB
Method: 1.Connect TP to waveform monitor 4MHz=0±1.5dB
2. Play Test Disc and Test Various 5.75MHz=0=4/-5dB
Frequencies Output level
3. Set Level of 0.5MHz to be 0dB. Compare
Output Level of others with 0dB.
6. Luminance S/N Equipment: Waveform Monitor (Expect VM700) Play 50% IRE:
Video Noise Meter Noise level -60dB
Test Signal: LT2-1,1-3, 50% Whirt (50IRE)
Test Point: Complex or S(Y) and Component(Y) Output
Method: 1.Connect TP to Video Noise Meter
2. Play Test Disc Signal Portion (50% IRE)
and Test Noise Level.
(Test L131 when Using VM700)
Test Equipment Condition: (4.2MHz LPF, SC Trap,
100kHz HFP. ON)
7. Chroma Signal AM, PM Equipment: Video Noise Meter (Expect VM700) Chroma Signal
S/N Test Signal: LT2-1,1-3 Noise Level
Test Point: Complex or S(C) Output - 50dB
Method: 1. Connect TP to Video Noise Meter
2. Play Test Disc Signal Portion and Test
Noise Level of Chroma Signal.
(Test L131 When Using VM700)
Test Equipment Condition:
(100Hz~1MHz BPF, SC Trap,. ON)
(VM700: 100kHz HPF,1MHz LPF, Single Line)
TEST CONDITIONS
3 4
PERFORMANCE SPECIFICATIONS - CONTINUED
PERFORMANCE SPECIFICATIONS - CONTINUED