EasyManua.ls Logo

Akai S01

Akai S01
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual
Sampling
The
operational
flow
for
manual
sampling
is
the same
as
in
auto-triggered
sampling—
(1
)
pressing
the
REC key,
(2)
adjusting
the
recording
level.
Then, as
first
mentioned
in
this
chapter, if the trigger
level
is
set
to
"100"
in
the
PROG.
NO./DATA
display,
the SOI
will be
ready
for manual
sampling.
*
In case
the
trigger
level
has
been set to
"0",
the S01
will
start
sampling as
soon as
the
bank
is
selected
(when
the
bank and
REC keys are
simultaneously
pressed).
Method:
1
.
Press
and
hold
down
the REC
key,
then press
the
desired
bank key
to
sample
in. The
REC LED
will
continue
blinking,
the
bank
LED
selected
will light.
If the
bank
already
contains a
sample,
it will be
erased
when
the bank
is
selected,
which
is
indicated
by
the
flashing
of the
PROG.
NO./
DATA
display.
2.
Press the
REC
key
to
start
sampling
or
press
any
key
other
than
the REC
key to
cancel
the
sampling.
3.
To stop
sampling,
press
any
key
in the
operation
panel
the
REC LED
will
go
out
to
indicate
that
sampling
is
stopped
and
the SOI
will
go to
Play
mode.
#
Effective Use
of
Manual
Sampling
Sometimes
the
very
first
part
of
a
sound is not
recorded
completely
when
using
the
auto-triggered
sampling
method,
for
example
when
recording
percussive
instruments
with
fast
attacks.
This
tends
to
produce
sounds
which lack
intensity.
This
problem
is
easily
solved by
manual
sampling.
If you
start
sampling
just
before the
required
source
sound is
input,
you
can
record
the
whole
sound
from
beginning
to
end,
without
losing the
attack
sound.
Of
course
in
this case,
you
may
have some
silence
at the
beginning
but
this
can be
removed
using
the
discard
function.
*
For
further
information
of
"discarding",
see
page
32.
Foot
Controlled
Sampling
An
optional
foot
switch
(normal-closed
type)
if
connected
to
the foot
switch
jack on
the
rear
panel
of
the SOI
,
you
can
start
and
stop
sampling
by foot.
This is
used
in
manual
sampling.
Method:
1
.
Press the
REC
key.
The
REC
LED
starts
blinking,
four
LEDs in
the
parameter
list
function as
the
recording
level
meter,
and
the PROG.
NO./DATA
display
shows
the
current
trigger
level.
If
the foot
switch
is
depressed at
this
point,
the
sampler
will go to
Play
mode.
2. Press
and
hold
down
the
REC key,
then
press the
desired
bank key
to
sample
in. The
REC
LED
will
continue
blinking, the
bank
LED
selected
will
light.
3
.
Depress
the
foot
switch
to
start
sampling,
or press
any
key
other
than
the
REC
key
to
cancel
the
sampling,
4. To stop
sampling,
depress
the
foot
switch
again,
the REC
LED
will go
out to
indicate
that
sampling
is
stopped,
and the
SOI
will
go
to
Play
mode.

Related product manuals