VI.
AMPLIFIER
ADJUSTMENT
1.
PLAYBACK
OUTPUT
LEVEL
(Pre-amplifier)
ADJUSTMENT
a)
Connect
a
High-sensitivity
V.T.V.M.
to
the
Line
Output
Jack
,
b)
Set
the
Tape
Speed
Selector
Switch
to
the
“7-1/2”
position.
c)
Playback
a
250
Hz
pre-recorded
tape.
d)
Adjust
the
VR29-1
(semi-fixed
resistor,
50
K—B)
of
the
Pre-amplifier
so
that
Line
Output
Voltage
indicates
1.228
V
(+4
dbm).
2.
WU
METER
SENSITIVITY
ADJUSTMENT
After
the
above
adjustment,
adjust
the
VR26-1
(semi-
fixed
resistor
2
K—B)
of
Chassis
Print
Board
(RD-526)
so
that
the
VU
meter
needles
indicate
exactly
0
VU,
denoted
by
dot.
3.
MAIN
AMPLIFIER
ADJUSTMENT
a)
As
shown
in
Fig.
1,
connect
the
AM
Meter
(100
mA—
150
mA
scale)
and
a
resistor
(8
20W)
to
the
External
Speaker
Jack.
b)
Set
the
Main
Amplifier
Volume
Contro!
to
minimum
so
that
VR31-1
and
VR31-2
(semi-fixed
resistor
2002-—B)
are
wound
counterclockwise.
c)
Set the
Power
Switch
to
the
“ON”’
position.
Adjust
VR31-1
and
VR31-2
so
that
the
AM
meter
needle
indicates
“0”.
d)
The
foregoing
should
acomplish
adjustment.
In
this
condition
Collector
Voltage
of
28D130
(Power
Output
Transistor)
should
read
26
to
27
V,
with
Collector
Current
at
70
to
100
mA.
TR3/-2
TR3I-3.
TR31-4
Fig.
1
25D130
2SD130
EXT.
SPEAKER
ammeter
150mA