EasyManua.ls Logo

Akai X-360D

Akai X-360D
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.
Relays
&
Solenoids
Actuated
for
Each
Operation
Function
Normal
Play
Reverse
Play
Recording
remreme
|
P|
|
pe
PP
O
mark
indicates
‘‘engaged”’.
STOP
Load
a
tape
and
depress
the
Power
Switch.
Current
flows
as
indicated
by
the
red
line
in
Figure
2,
driving
the
Main
Motor
in
the
normal
direction,
and
lights
the
VU
Meter
Lamp.
PLAY
With
the
Recorder
set
to
STOP,
depress
the
FORWARD
Button.
Current
flows
as
indicated
in
Figure
3,
actuating
the
PLY,
QT,
and
MAG
Relays
and
the
P.R.
and
BRK
Solenoids.
Tape
is
fed
in
the
normal
(forward)
direction
at
a
constant
speed
as
current
is
supplied
through
R201
and
R206
to
Left
and
Right
Reel
Motors.
To
provide
increased
start-
ing
torque
for
the
Reel
Motors,
the
QT
Relay
is
actuated
approximately
0.2
second
after
the
FORWARD
Button
is
depressed,
partially
shorting
R201
and
applying
higher
voltage
to
the
Take-up
Motor.
The
Block
Diagram
clearly
show
the
opera-
.
tion
of
the
individual
relays.
FAST
FORWARD
When
the
FAST
FORWARD
Button
is
depressed,
current
{lows
as
indicated
in
Figure
4,
actuating
the
FF,
MAG,
QT,
and
TIM
Relays
and
the
BRK
Solenoid.
100V
is
supplied
to
the
Take-up
Motor,
and
13V
is
fed
to
the
Supply
Motor
through
R203,
for
back
tension
application
during
FAST
FORWARD
feed.
REWIND
When
the
REWIND
Button
is
depressed,
current
flows
as
indicated
in
Figure
5,
actuating
the
RWD,
QT,
MAG,
DS,
and
TIM
Relays
and
the
BRK
Solenoid.
100V
is
supplied
to
the
Supply
Motor
and
13V
is
fed
to
the
Take-up
Motor
through
R203,
for
back
tension
application
during
REWIND.
20
Magnetic
Brake
When
the
STOP
Button
is
depressed
during
FAST
FORWARD
or
REWIND,
the
Magnetic
Brake
smoothly
and
quickly
stops
the
fast
moving
tape.
a)
When
the
STOP
Button
is
depressed
during
REWIND,
Condenser
C44-7
(10
pF)
is
dis-
charged
through
VR44-1
(100K
&)
and
R44-4
(6.8K
Q),
as
shown
in
Figure
6.
Discharge
Time
Constant
is
2
seconds
with
SW102
set
to
STANDARD,
or
4
seconds
when
set
to
1
or
1/2
mil.
During
discharge
Tr44-1
(2SC372)
and
Tr44-2(2SC728),
as
well
as
TIM
and
DS
Relays
remain
engaged.
65V
AC
is
supplied
to
the
Take-up
Motor
through
R205
(400
©)
and
DC
current
is’
supplied
to
the
Take-up
Motor
Sub
Coil
through
R205(1K
Q)
and
Diode
(10D4),
allowing
the
Take-up
Motor
to
serve
as
a
Brake.
b)
When
the
STOP
Button
is
depressed
during
FAST
FORWARD,
the
TIM
Relay
remains
engaged,
and
supplies
hoth
AC
and
DC
to
the
Supply
Motor
which
serves
as
a
Brake
for
the
fast
moving
tape.
When
the
Magnetic
Brake
Contiol
Switch
SW-102
is
sel
tv
1
or
1/2
mil,
D44-11
and
R204
are
cut
out
from
the
circuit
and
AC
only
is
supplied
to
the
Motor.
Because
the
Brake
Band
only
assists
the
Magnetic
Brake,
Brake
Tension
(Braking
Power)
applied
by
the
Brake
Band
can
be
of
a
_
comparatively
smaller
value
than
usual.

Related product manuals