Defines temperature limits for T1 climate models.
Defines temperature limits for T3 climate models.
Controls appliance power on and off.
Used to select the operation mode.
Allows adjustment of indoor fan motor speed.
Adjusts preset room temperature and timer settings.
Controls airflow direction adjustment.
Activates fuzzy logic operation.
Sets or cancels timer operations.
Manages sleep mode operation.
Starts or stops fast cooling.
Illustrates the refrigeration cycle for cooling-only models.
Shows the refrigeration cycle for heat pump models.
Details safety mechanisms like delays and protection.
Explains automatic and manual louver movement.
Describes operation specifics for the cooling mode.
Details the operation of the dry mode.
Specifies heating mode operation for heat pump units.
Prevents cold air discharge during heating.
Automatic mode selection based on room temperature.
Automatic fan speed control based on temperature.
Manual and auto fan speed settings.
Emergency operation via indoor unit buttons.
Functionality for automatic restart after power loss.
Operation and timing of defrost cycles.
Setting and cancelling timer functions.
Energy-saving sleep mode functionality.
Guidelines for choosing optimal indoor and outdoor unit placement.
Instructions for drilling piping holes.
Steps for indoor unit piping and drainage setup.
Procedures for connecting outdoor unit pipings and cables.
Verifying drainage and connecting indoor unit cables.
Purging air from the system.
Procedure for purging air during installation.
Process for pumping down refrigerant before re-installation.
Steps for re-purging air for re-installation.
Balancing refrigerant after gas leakage.
Evacuating the system when refrigerant is completely leaked.
Charging refrigerant into the system after evacuation.
Diagnosing issues within the refrigeration cycle.
Correlation between AC condition, pressure, and current.
Methods to diagnose compressor malfunctions.
Table of symptoms, causes, and corrective actions.
Steps for checking the control circuit functionality.
Visual breakdown of the indoor unit components.
Visual breakdown of the AC-S13CK outdoor unit.
Visual breakdown of the AC-S13HK outdoor unit.
List of parts for the AC-S13CK indoor unit.
List of parts for the AC-S13HK indoor unit.
List of parts for the AC-S13CK outdoor unit.
List of parts for the AC-S13HK outdoor unit.
| Power Supply | 220-240V, 50Hz |
|---|---|
| Noise Level (Indoor) | 38 dB(A) |
| Refrigerant | R410A |
| Type | Split |
| Cooling Capacity | 12000 BTU/hr |
| Noise Level (Outdoor) | 52 dB |
| Operating Temperature (Cooling) | 18°C to 43°C |
| Outdoor Unit Dimensions (WxHxD) | 780 x 540 x 250 mm |