Do you have a question about the Aktobis WDH-310EKW and is the answer not in the manual?
Air circulation | 100 m³/h |
---|---|
Power consumption | 220 W |
Refrigerant | R290 |
Water tank capacity | 2 liters |
Weight | 10.5 kg |
Dehumidification Capacity | 12 liters/day |
Suitable for rooms up to | 25 m² |
Operating temperature range | 5°C - 35°C |
Steps for first-time operation, including liquid settling and compressor delay.
Guidance on using humidity meters and understanding performance factors.
Ensuring a safe environment and work area before and during repairs.
Checking for refrigerants and having fire extinguishers ready.
Precautions against ignition sources when working with refrigerants.
Ensuring proper ventilation and testing refrigerant/electrical equipment.
Safe handling of intrinsically safe components and checking wiring integrity.
Methods for detecting leaks and handling flammable refrigerants safely.
Requirements and precautions for filling the refrigerant system.
Steps for safely decommissioning the unit and handling refrigerant.
Marking equipment after service and standard reprocessing practices.
Identification of external components like blower output, display, and air intake.
Explanation of the control panel buttons and display indicators.
Steps for initial setup, including castor attachment and power connection.
How to set target humidity and select fan speed for operation.
Using the timer to set remaining or start times for the unit.
Instructions for connecting the dehumidifier to the 'Tuya Smart' app.
Procedure for emptying the condensation tank when the full indicator is on.
Instructions for attaching a hose for continuous condensation drainage.
Advice on placement, room conditions, and avoiding damage.
Safe methods for cleaning the exterior of the dehumidifier.
Procedure for removing and cleaning the air filter for optimal performance.
Details on model, voltage, power, capacity, dimensions, weight, and range.
Diagnosing issues with insufficient dehumidification or low water collection.
Identifying causes and solutions for operational noises like rattling.
Diagnosing and resolving issues related to water leakage from the unit.
Details on tested safety, CE, EMC, and RF conformity standards.
Guidelines for environmentally sound disposal of the appliance within the EU.