477 296_b I 08/2014
HWA 4000 / HWA 4500 / HWA 6000/5
Betriebsanleitung

Questions and Answers

  • G
    gina89Aug 9, 2025
    What to do if my AL-KO HWA 6000/5 Premium shows 'ALARM CHECK PRE 1.5 BAR'?
    • T
      Tiffany BryantAug 10, 2025
      The 'ALARM CHECK PRE 1.5 BAR' message indicates that the AL-KO Water Pump has switched off as a protection against overheating. This is often due to a fault on the pressure side, such as a leak. Even small leaks on water taps and toilets can cause the system pressure to drop. You should check the pressure line and draw-off points for leaks. Also, check and clean the check valve in the filter chamber. After rectifying the fault, confirm with SET to restart the pump. Be aware of potential hot water when the restart occurs.
  • C
    Cassidy OlsonAug 29, 2025
    What to do if AL-KO HWA 6000/5 Premium Water Pump displays 'CHECK SUCTION SI 0.0 BAR'?
    • L
      luis13Aug 29, 2025
      The message 'CHECK SUCTION SI 0.0 BAR' appears for 20 seconds. The AL-KO Water Pump will attempt to rectify the fault itself for 90 seconds. No action is required from you during this time. However, if the fault persists after 90 seconds, the pump will switch off as a dry-run protection.
  • A
    allenrebeccaNov 17, 2025
    Why does my AL-KO Water Pump display 'ALARM SUCTION SI 0.0 BAR'?
    • T
      thorntonadamNov 18, 2025
      The 'ALARM SUCTION SI 0.0 BAR' message means that the AL-KO Water Pump has switched off as a dry-run protection. This can occur due to several reasons: * A leak on the suction side. Check the suction valve and suction hose. * A leak on the filter bowl. Check the filter bowl seal and retighten the filter bowl. * A leak on the filter chamber drain screw. Check the drain screw seal and retighten the drain screw. * The end of the hose is not in the water, or the water reservoir is empty, causing the pump to draw in air. Ensure the suction line is always at least 30 cm under the surface of the water. * The filter is heavily contaminated. Clean the filter. * A suction line blockage. Remove any dirt from the suction area. * The flow rate is less than 300 l/h. Increase the flow rate...

Summary

Product Description

Designated Use

Specifies the intended private use for garden watering and house water supply.

Safety Instructions

General Safety Warnings

General safety warnings regarding machine operation and extension cables.

Electrical Safety

Warnings and recommendations for electrical connections, including RCD usage.

Assembly

Startup

Initial Start-up of the Unit

Steps for initial commissioning, including language selection and filling.

Operation

Maintenance and Care

Troubleshooting

AL-KO HWA 6000/5 Premium Specifications

General IconGeneral
Max Flow Rate6000 l/h
Max Pressure6 bar
Max Suction Depth8 m
Max Delivery Height60 m
Pump Outlet Ø1 inch
Integrated Pre-filterYes
Pump HousingStainless steel
Max Head60 m
Voltage230 V
Frequency50 Hz
Inlet/Outlet Diameter1 inch
Protection ClassIPX4
Pump MechanismJet