Veto Stoker Boilers
30, 60, 75, 80, 100, 120, 150, 220 kW
User Manual
Installation, Operation, and Service
Retailer:

Table of Contents

Questions and Answers

  • C
    Christina SnyderAug 2, 2025
    Why is my Ala-Talkkari Boiler water boiling?
    • D
      David PetersonAug 2, 2025
      If the Ala-Talkkari Boiler water is boiling, it could be due to several reasons: * A faulty adjustment of the burner. To fix this, adjust the relation between the stand-by fire and the interpulse time or the settings of the overheating protector. * A broken boiler thermostat. If this is the case, replace the boiler thermostat. * A change in the fuel type. In this case, adjust the feeding values according to the feeding table. * A set temperature for the boiler thermostat that is too high. Adjust the boiler thermostat temperature to 80°C or less. * A pause time that is too short. Adjust the operating condition pause time to be longer.
  • C
    Crystal MarshallAug 6, 2025
    What to do if Ala-Talkkari Veto 30 kW system does not produce heat even though the boiler is warm?
    • N
      Nicholas KnightAug 6, 2025
      If your Ala-Talkkari Boiler system does not produce heat even though the boiler is warm, consider the following: 1. Not enough water in the boiler. Turn off the device and let it cool completely before adding water, as adding cold water to a hot boiler can cause an explosion. 2. The circulation water pump is not rotating. Determine the cause of the pump malfunction and repair or replace it. 3. Air in the heating network. Bleed the air from the heating network. 4. A valve between the boiler and the piping is reducing or preventing water circulation. Open the valve. 5. The thermostat of the water accumulator pump is broken. Replace the thermostat.
  • A
    Ashlee JacksonAug 11, 2025
    How to fix Ala-Talkkari Boiler solid fuel burner that does not start?
    • J
      James SnowAug 11, 2025
      If the Ala-Talkkari Boiler's solid fuel burner does not start, it could be due to: * The overheating protector of the boiler thermostat has gone off. Push the reset button if the temperature has fallen sufficiently low. * An active alarm. Check the control unit for alarm messages and follow the instructions there.
  • J
    Joseph NortonAug 16, 2025
    Why is tap water from my Ala-Talkkari Veto 30 kW Boiler not sufficiently warm?
    • B
      Brittany FloresAug 17, 2025
      If the tap water is not sufficiently warm when using your Ala-Talkkari Boiler, here are a few potential causes and solutions: * The water coil might be connected the wrong way round. A plumber will need to reconnect the coil correctly. * The boiler or the water accumulator might not be warm enough. Try heating it more. * A lot of water might have been used recently. Wait until the water becomes warm again. * The mixing valve might be jammed. Replace the valve. * The water piping might be clogged. Check the condition of the piping.
  • T
    Tiffany GarciaAug 21, 2025
    Why does my Ala-Talkkari Veto 30 kW have a smoky flame?
    • T
      Thomas DavisAug 21, 2025
      A smoky flame in your Ala-Talkkari Boiler could be caused by: * Faulty burner adjustment or a cold fire jet. Allow the fire jet to warm up or readjust the burner. * High moisture content in the fuel. Replace the fuel with drier fuel. * Low boiler temperature for an extended period. Faulty connection of the water accumulator. See 5.6 Installing plumbing. * Insufficient air supply to the burner. Clean the burner and blower according to the user manual. Readjust the feeding and blowing intervals according to the feeding table.
  • S
    Sharon BrooksNov 25, 2025
    How to improve weak draft in the flue of Ala-Talkkari Boiler?
    • T
      Tammy WhiteheadNov 25, 2025
      A weak draft in the flue of your Ala-Talkkari Boiler can result from several issues: * The junction between the boiler and the flue is not airtight. Seal it up using mineral wool, for example. * There is a blockage in the flue outlet. Clear the blockage. * The sweeping door in the flue is left open. Close it tightly. * The chimney is moist and cold. Burn paper to warm up the chimney. * There is partial vacuum in the building, causing the air flow in the flue to go in the wrong direction. Shut the doors and other holes in the boiler room from which the suction comes. * The moisture content of the fuel is too high. Change the fuel or add dry fuel. * The boiler is situated far from the chimney, with the aggregate too long in the horizontal plane. The flue must be made to rise s...

Summary

2. General Safety and Warnings

4. Technical Data

5. Installation

6. Commissioning

6.1. Pre-Use Checks and Network Preparation

Details essential checks and heating network preparation steps before the boiler is put into actual operation.

7. Operation

8. Emergency Situations

8.1. Fire, Overheating, and Overpressure Procedures

Details actions for fires, overheating, and overpressure, including safety precautions and immediate steps.

8.2. Chimney Fire Response

Instructs users to call the emergency number immediately in case of a chimney fire.

9. Service

10. Troubleshooting

10.1. Boiler Operation Problems (Boiling, No Start)

Addresses boiling water and burner start-up problems, listing causes and solutions.

10.2. System Performance Issues (Heat, Water Temp, Draft)

Troubleshoots systems with no heat, insufficient water temperature, smoky flames, and weak draft.