6410T0008_REV_G
USER MANUAL
ACS-50 CONTROL PANEL
ASSA ABLOY ENTRANCE SYSTEMS
975-A Old Norcross Road
Lawrenceville, Ga 30046
800-252-2691 Tel
770-338-5034 Fax
www.albanydoors.com

Table of Contents

Questions and Answers

  • C
    Craig CruzAug 4, 2025
    Why are LEDs 7, 8, 9, or 15 not on and Albany Control Panel is locked?
    • N
      Nathaniel NguyenAug 4, 2025
      If LEDs 7, 8, 9, or 15 are not illuminated when the system powers up, the Albany Control Panel will enter a locked state. To resolve this, reset the power and identify which LED is not lit. Then, inspect the corresponding item to ensure the light turns on.
  • K
    Kara PetersAug 11, 2025
    What to do if Albany Control Panel shows Red Lamp Alarm and LED 20 (OUTPUT Error)?
    • J
      James NicholsonAug 11, 2025
      If the Albany Control Panel displays a Red Lamp Alarm along with LED 20 indicating an OUTPUT Error, check panel stop terms 82-84.
  • A
    ann47Aug 19, 2025
    What to do if Albany Control Panel terminals 33 and 34 don't have 24VDC?
    • J
      Jose HillAug 19, 2025
      If terminals 33 and 34 of the Albany Control Panel do not have 24VDC, check the fuses. Also, verify terminals 63 and 64 for 24VAC.
  • K
    khurleyAug 27, 2025
    What to do if Albany Control Panel is not showing LEDs 2 & 4?
    • L
      Linda HarrisAug 27, 2025
      If the Albany Control Panel is not showing LEDs 2 & 4, check the wiring and/or jumpers at terminals 1& 2 or 1A & 2A.

Summary

ACS-50 Controller Specifications

Rapid Roll Drive Units Specifications

Specifications for Albany Door Systems Rapid Roll Drive Units.

ACS-50 Electrical Practices

General Electrical Installation Guidelines

Covers electrical practices, high voltage warnings, and wiring guidelines for safe installation.

ACS50 Control Panel Interior (Single Speed)

ACS-50 Motherboard Layout

ACS50 Control Panel Interior (Two Speed)

WIRING TO PANEL

Incoming Power and Voltage Settings

Details on connecting incoming power and setting the voltage selector jumper.

Safety Edge and Electric Edge Wiring

Wiring instructions for pneumatic and electric safety edges.

Ground Bar and Motherboard Connections

Guidelines for grounding and connecting motherboard wiring.

ACS-50 Settings and Electrical Startup

CPU Card Switch Settings

Configuration of CPU card DIP switches and jumpers for operation.

Setting Opening and Closing Functions

Electrical Start Up Procedures

Limit Switch Coarse Adjustment

Procedure for setting the initial door open and closed limits.

Turning on the Door Controller

Steps for powering up the controller after adjustments and initial test.

Door Operation Checks and Adjustments

Hold-to-Run Function

Explains the hold-to-run mode and its reset conditions.

Limit Switch Fine Adjustment

Fine-tuning the door's open and closed limit positions.

Monitoring and Safety Circuit Operation

Runtime Monitoring and Faults

Internal timer for door run time and controller fault indications.

Safety Circuit Limit Box (GFA)

Details on terminals and function of GFA safety circuit limit boxes.

Pressure Switch Adjustment

TROUBLESHOOTING Controller Faults

Controller Faults and Indications

Table of controller faults, error descriptions, and LED indications.

WIRING DIAGRAMS - BONFIGLIOLI MOTORS

WD501-BF002: ACS50 1 Speed - Bonfiglioli Motor & Limit (Models 570 & 670)

Wiring diagram for ACS50 1-speed Bonfiglioli motor models 570 & 670.

WIRING DIAGRAMS - GFA OPERATORS

WD501-GF002: ACS50 GFA Operator Wiring 1-Speed

Wiring diagram for ACS50 GFA operator, 1-speed.

CONTROL PANEL REPLACEMENT PARTS

Albany ACS-50 Specifications

General IconGeneral
BrandAlbany
ModelACS-50
CategoryControl Panel
LanguageEnglish