Generator Set
LÜTFEN BU KILAVUZU KKATLE OKUYUNUZ VE SAKLAYINIZ.
MG 309
MG 311
MG 314
MG 315
MG 320
MG 323
MG 330
TN 307
TS 309
TS 315
TS 320
TS 323
TS 330
TS 343
Models
Operation Manual
PLEASE READ AND KEEP THIS MANUAL CAREFULLY.
MN 305
MN 307
MS 306
MS 307
MS 310
MS 312
MS 316
MS 323
MS 330
TG 306
TG 309
TG 311
TG 314
TG 315
TG 316
TG 320
TG 323
TG 330
TG 343

Questions and Answers

  • N
    nleeAug 16, 2025
    What to do if the speed lamp is on and there is no AC power from my Albo marine Portable Generator?
    • H
      hammondannetteAug 17, 2025
      If the speed lamp is on and it's not possible to take AC power from your Albo marine Portable Generator due to no voltage generation, first, make sure the circuit breaking fuse is in the ON position. If that doesn't work, the fuse may be faulty and needs replacement. If these steps don't solve the issue, the alternator may be faulty, and you should report it to authorized service.
  • J
    justinjohnsonAug 22, 2025
    What to do if the speed lamp is on and the output voltage is excessively low on my Albo marine MN 305 Portable Generator?
    • T
      Tiffany CastroAug 22, 2025
      If the speed lamp is on and the output voltage or frequency is excessively low on your Albo marine Portable Generator: 1. Disable the PTO if it's taking too much energy from the engine. 2. Turn off high-resistance devices to reduce excessive electrical load. 3. Repair fuel leaks and remove air bubbles from the fuel system. 4. Bleed the air from the fuel system. 5. Use fuel that meets the engine manufacturer's specifications. 6. Ensure the engine has adequate operating air. 7. Correct the voltage adjustment regulator. If the issue persists, the alternator may be faulty, and you should contact an authorized dealership.
  • D
    Dr. Juan McgeeAug 25, 2025
    What to do if the starting lamp is on and the engine won't start on my Albo marine MN 305 Portable Generator?
    • D
      Douglas PayneAug 26, 2025
      If the engine of your Albo marine Portable Generator cannot be started due to starter incapability and the starting lamp is on: * Turn the circuit breaking fuse to the OFF position if the alternator is taking too much energy. * Clean the terminals, check the battery charge and cables, and tighten connections if the battery charge is inadequate or there's loose contact in the battery cables and connection points.
  • A
    alexis66Aug 30, 2025
    What to do if the speed lamp is on and the output voltage is excessive on my Albo marine MN 305?
    • B
      Barry DuncanAug 30, 2025
      If the speed lamp is on and the output voltage or frequency is excessive on your Albo marine Portable Generator: * Check and replace the circuit breaking fuse if there is an error. * Repair fuel leaks and remove air bubbles from the fuel system if there is a fault. * Bleed the air from the fuel system if there is air inside. * Correct the adjustments of the voltage adjustment regulator if it is faulty. If the issue continues, contact an authorized dealership as the alternator may be faulty.
  • A
    Annette BruceSep 2, 2025
    What to do if the charging fault lamp is on and batteries are not charging on my Albo marine MN 305?
    • S
      Susan BautistaSep 2, 2025
      If the charging fault lamp is on and the batteries are not charging adequately on your Albo marine Portable Generator: * Clean the terminals, check the battery charge and cables, and tighten connections if there is inadequate battery charge or loose contact in battery cables and connection points. * Adjust the V-belt slackness properly to adjust the belt sag to 6-8mm if the V-belt driving the battery charging alternator is slackened. * Perform necessary measurements and disable the device when required if interference with battery-supplied devices may reduce the desired effect of the charge.
  • R
    roger25Sep 4, 2025
    Why is the oil pressure lamp on in my Albo marine MN 305 Portable Generator?
    • R
      Robert RobinsonSep 5, 2025
      If the oil pressure lamp is turned on in your Albo marine Portable Generator, check the oil level and ensure it is at the proper level. Also, inspect the lubrication system for leaks and repair them properly.
  • B
    Brandon GalvanSep 7, 2025
    What to do if the speed alarm lamp is on and the engine stopped on my Albo marine MN 305 Portable Generator?
    • K
      Karen BanksSep 7, 2025
      If the speed alarm lamp is on and the engine of your Albo marine Portable Generator stopped by itself, check for: * Leaks in the fuel system: Repair fuel leaks and remove air bubbles. * Leaks in the cooling system: Repair leaks and add coolant to the proper level. * Leaks in the lubrication system: Repair any leaks.
  • K
    Kristy SimmonsSep 10, 2025
    What to do if there is no response from the remote control panel of my Albo marine Portable Generator?
    • H
      hernandezelizabethSep 10, 2025
      If there is no response from the electronic remote control panel module of your Albo marine Portable Generator: * Ensure the remote operation control switch on the generator is turned “ON”. * Ensure the emergency stop button or DC protection switch is turned “ON”. * Clean the terminals, check the battery charge and cables, and tighten connections if there is inadequate battery charge or loose contact in battery cables and connection points.
  • T
    Terry WatsonSep 12, 2025
    What should I do if the carbon monoxide detector is beeping in my Albo marine MN 305?
    • J
      Jason SandersSep 12, 2025
      If the carbon monoxide detector in your Albo marine Portable Generator gives a warning signal, immediately move everyone to open air, ensure proper ventilation, and seek medical assistance if required, as there may be excessive carbon monoxide build-up inside the vessel.
  • A
    Ariana AllenNov 18, 2025
    What to do if the excessive heat lamp is on and the engine is overheated on my Albo marine MN 305 Portable Generator?
    • E
      erneststeeleNov 18, 2025
      If the excessive heat lamp is on and the engine of your Albo marine Portable Generator is overheated: * Check and add engine coolant if the level is inadequate. * Ensure the sea water inlet is not clogged by cleaning the filters and pump inlets to provide sufficient sea water intake. * Inspect cooling system pipes and hoses for twists, punches, or leaks, repairing as necessary. * Adjust the V-belt slackness driving the engine coolant circulation pump to have a belt sag of 6-8mm. * Make sure the siphon kit is properly drained and operating. * Replace the sea water pump internal gear if it's faulty. * Clean the heat exchanger if it's blocked or dirty. * Check for and clear any blockages in the installation connection points on the sea vessel body. * Replace the thermostat ...