ACM 2000
Multi-channel Controller
User’s Manual
--Réalisation/Publication: Alcatel Vacuum Technology France - User’s Manual - Ed 03 - Date : 09/2010 - P/N : 113162 *113162*
Question and Answer IconNeed help?

Do you have a question about the Alcatel Vacuum Technology adixen ACM 2000 and is the answer not in the manual?

Overview

The Adixen ACM 2000 is a multi-channel controller designed to provide power, control, and pressure display for one, two, or three gauges simultaneously. It can be operated via its front panel or externally through a computer using its built-in RS232 link.

Function Description:

The ACM 2000 supports a variety of gauges, including:

  • PIRANI gauges: AP 2004 - APN 2004
  • Combined PIRANI/Cold cathode gauges: ACC 2009
  • Combined CRYSTAL/Hot cathode gauges: AHC 2010
  • Capacitive gauges: ASD 200X, ARD 200X series

The controller performs automatic testing upon start-up, identifies connected gauges, and continues operation with the parameters active before power-off. It switches to "Measuring" mode, displaying the sensor that was active previously, and adapts parameters if gauges have changed.

Important Technical Specifications:

  • Power Supply: 100-240 VAC, 50/60 Hz, < 100 VA.
  • Weight: 2.1 kg.
  • Operating Environment: Inside use only, max altitude 2000 meters, pollution level II, IP 30 protection.
  • Temperature Range: Storage: -20°C to +60°C; Running: +5°C to +50°C.
  • Relative Humidity: < 70%.
  • Number of Channels: 3.
  • Gauge Power Supply: 24 VDC ± 5%, 13 W, 900 mA current protection by resettable fuse.
  • Set Point Outputs: 2 (on gauge connector), ON: +24 V, OFF: 0 V.
  • Remote Control: D-Sub 15P (female) x3.
  • RS232 Interface: D-Sub 9P (male), 9600, 19200, or 38400 Bauds, 8 data bits, 1 stop bit, no parity bit.
  • Analog Output: 0-10 V for each measuring channel, impedance 200 Ω.
  • Display: LCD TFT color, 100 ms refresh time.
  • Measurement Accuracy: Amplifier: 0.02% FS, Offset: ≤ 0.05% FS.
  • Filter Time Constant: Slow: t = 750 ms (fq = 0.2 Hz); Normal: t = 150 ms (fq = 1 Hz); Fast: t = 20 ms (fq = 8 Hz).
  • Pressure Units: mbar, Pa, or Torr.
  • Zero Function: Available for Capacitive gauges only.
  • Data Recording: Up to 24 hours of pressure data stored in memory (firmware V1.11 or higher), one data record per second per channel. Data can be retrieved via RS232.

Usage Features:

  • Multi-channel Operation: Controls and displays pressure for up to three gauges simultaneously.
  • Front Panel Control: Intuitive operation via touch buttons and a display.
  • Display Modes: Digital readout (default), Graph display, and Analog display. Users can cycle through these modes using the "DISP" button.
  • Configurable Start-up Display: The default digital readout can be changed to graph or analog display.
  • Channel Naming: Channels can be assigned custom names for easier identification.
  • Filtering: Three filter settings (Slow, Normal, Fast) are available to smooth measurement information, aiding with unstable processes or fluctuating signals.
  • Gas Correction Factor: Corrects measurements for gases other than nitrogen, influencing readout and set point switching thresholds (not available for capacitive gauges).
  • Set Point Management: Two set points per channel are available to control external devices. These set points have high and low thresholds and can be configured to open or close based on pressure signals.
  • RS232 Communication: Allows external control and data retrieval via a computer. Baud rate and end-of-line characters are configurable.
  • Settings Lock: A "LOCK" function prevents unauthorized modification of settings.
  • Pressure Units: Selectable units include mbar, Torr, and Pascal.
  • Digit Display: Choose between 2 or 3 digit display for values (not for capacitive gauges).
  • Decimal Point Position: For capacitive gauges, the decimal point position in the displayed pressure value can be modified, with the exponent changing accordingly.
  • Full Scale Setting: For capacitive gauges, the top value in the measuring range can be specified.
  • Degassing Function (AHC 2010): Cleans the electrode system of combined CRYSTAL/Hot Cathode gauges by heating, permitted for pressures < 5x10-3 mbar.
  • Hot Cathode Deactivation (AHC 2010): Deactivates the hot cathode gauge, displaying only CRYSTAL gauge pressure values.
  • Zero Function (Capacitive Gauges): Assigns a measured pressure value as a datum point, allowing negative readings for pressures below this value (only within -0.2V to +0.2V analog output range).
  • Data Recording: Start and stop pressure data recording by pressing the "CH" key for two seconds while in Graph display mode.

Maintenance Features:

  • Decontamination and Product Recycling: Adixen products at the end of their service life must be returned to the manufacturer for decontamination and reuse, in compliance with Directive 2002/96/CE and 2002/9/CE. A safety questionnaire must be filled out in advance.
  • Self-Tests: The controller includes various test modes accessible via the "SET" button:
    • Analog/Digital converter test: Checks gauge input voltage and gauge identification resistance.
    • Controller display test: Visually checks display quality for dead pixels.
    • Memory tests: Checks "Live" memory (RAM) and "Program" memory (EEPROM).
    • Controller interface tests: Verifies recorder output voltage, input/output relay switching, front panel buttons, and RS232 link data transfer.
  • Factory Default Settings: All settings can be restored to their factory default values at any time.
  • Error Messages: A comprehensive list of error messages is provided, indicating possible faults and recommended actions for troubleshooting.
  • Rack Mounting: The controller can be rack-mounted, but requires 20 mm free space around it and a fan to avoid overheating if ambient temperature exceeds 50°C.